Trane / AIR-SOURCE HEAT PUMP

5TWX6036A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 10

374 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,000–35,400BTU/h

Each efficiency range summarizes published EPA records for 5TWX6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 374 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5374 / 374
EER2 · BTU/Wh11.2–12374 / 374
HSPF2 · BTU/Wh7.8–8.1374 / 374
Cooling capacity · BTU/h32,000–35,400374 / 374
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,400374 / 374
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200374 / 374
Heating capacity at 5°F / −15°C · BTU/h16,900–17,700374 / 374
COP at 5°F / −15°C2.22–2.48374 / 374
Equipment / loop typeHP - Split System374 / 374
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)374 / 374
Compressor stagingSingle stage374 / 374
Connected capabilityNo374 / 374

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21811052615.208.10170002.36EPA 4575303
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21811052515.208.10173002.35EPA 4575304
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21811052415.208.00171002.35EPA 4575305
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21811052315.208.00171002.35EPA 4575306
5TXCB006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21811052115.208.00172002.35EPA 4575308
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21811052015.208.10172002.35EPA 4575309
5TXCB006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21811051915.208.10169002.34EPA 4575310
5TXCB006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21811051815.207.80170002.34EPA 4575311
5TXCB006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21811051715.208.10169002.38EPA 4575312
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21811051615.208.10175002.32EPA 4575313
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21811051515.208.10172002.35EPA 4575314
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21811051415.208.10172002.35EPA 4575315
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21811051315.208.10172002.36EPA 4575316
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21811051215.208.10172002.36EPA 4575317
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21811051115.208.10175002.32EPA 4575318
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21811051015.208.10175002.32EPA 4575319
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21811050915.208.10171002.36EPA 4575320
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21811050815.208.10171002.36EPA 4575321
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21811050715.208.10173002.35EPA 4575322
5TXCB006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21811050615.208.10170002.34EPA 4575323

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →