Trane / AIR-SOURCE HEAT PUMP

5TWX6030A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 5

139 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,200–29,600BTU/h

Each efficiency range summarizes published EPA records for 5TWX6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16139 / 139
EER2 · BTU/Wh11.7–12139 / 139
HSPF2 · BTU/Wh7.8–8.1139 / 139
Cooling capacity · BTU/h27,200–29,600139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800139 / 139
COP at 5°F / −15°C2.12–2.28139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TEM6B03AV21+TDR+TSTATAHRI reference: 21811014015.208.10135002.15EPA 4575109
5TEM4D05AC41+TDR+TSTATAHRI reference: 21811013815.208.10134002.17EPA 4575110
5TEMCB03AV31+TDR+TSTATAHRI reference: 21811014515.208.10134002.18EPA 4575113
5TEM6D07AV51+TDR+TSTATAHRI reference: 21811014315.208.10133002.27EPA 4575114
5TEM6D06AV41+TDR+TSTATAHRI reference: 21811014215.208.10133002.27EPA 4575115
5TXCB006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21811021215.207.80131002.19EPA 4575529
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21811020715.207.80132002.21EPA 4575530
5TXCB006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21811020315.208.10133002.17EPA 4575531
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21811020215.208.10133002.17EPA 4575532
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21811019715.207.80133002.18EPA 4575533
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21811019615.207.80133002.18EPA 4575534
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21811246115.208.10134002.17EPA 4575552
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21815934615.208.10131002.22EPA 4576597
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21815934515.207.80133002.18EPA 4576598
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21815934415.207.80133002.18EPA 4576599
5TEM6D04AV31+TDR+TSTATAHRI reference: 21815933515.208.10134002.24EPA 4576600
5TAMXD04AV31+TSTATAHRI reference: 21815933415.208.00133002.17EPA 4576601
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21815932915.207.80134002.18EPA 4576604
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21815932815.207.80134002.18EPA 4576605
5PX*BD06AS3+TSTAT+ furnace: S9V2B040D3VSBAHRI reference: 21815932715.207.80132002.17EPA 4576606

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →