Trane / AIR-SOURCE HEAT PUMP

5TWX6030A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 4

139 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,200–29,600BTU/h

Each efficiency range summarizes published EPA records for 5TWX6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16139 / 139
EER2 · BTU/Wh11.7–12139 / 139
HSPF2 · BTU/Wh7.8–8.1139 / 139
Cooling capacity · BTU/h27,200–29,600139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800139 / 139
COP at 5°F / −15°C2.12–2.28139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21811008615.207.80133002.17EPA 4575020
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21811008515.207.80133002.17EPA 4575021
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21811008415.207.80134002.18EPA 4575022
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21811008315.207.80134002.18EPA 4575023
5PX*BD06AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21811008015.207.80133002.18EPA 4575024
5PX*BD06AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21811007915.207.80133002.18EPA 4575025
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21811007815.207.80134002.18EPA 4575026
5PX*BD06AS3+TSTAT+ furnace: S9V2B080D4VSBAHRI reference: 21811007015.207.80133002.16EPA 4575027
5PX*BD06AS3+TSTAT+ furnace: S9X2B080D4PSBAHRI reference: 21811006915.207.80133002.16EPA 4575028
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21811003115.207.80133002.18EPA 4575030
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21811003015.207.80133002.18EPA 4575031
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21811023015.208.10132002.19EPA 4575097
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21811022815.207.80135002.18EPA 4575099
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21811022715.207.80135002.18EPA 4575100
5TXCC007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21811022615.208.10133002.20EPA 4575101
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811022415.208.10134002.19EPA 4575102
5TEM4D04AC31+TDR+TSTATAHRI reference: 21811013715.208.10133002.17EPA 4575103
5TEM4B03AC31+TDR+TSTATAHRI reference: 21811013615.208.10134002.19EPA 4575104
5TAM5D05AC31+TSTATAHRI reference: 21811013115.208.00132002.16EPA 4575107
5TEM6D05AV41+TDR+TSTATAHRI reference: 21811014115.208.10133002.23EPA 4575108

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →