Trane / AIR-SOURCE HEAT PUMP

5TWX6030A1

16 Single-Stage Heat Pump with WeatherGuard Top · source records, page 2

139 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,200–29,600BTU/h

Each efficiency range summarizes published EPA records for 5TWX6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16139 / 139
EER2 · BTU/Wh11.7–12139 / 139
HSPF2 · BTU/Wh7.8–8.1139 / 139
Cooling capacity · BTU/h27,200–29,600139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800139 / 139
COP at 5°F / −15°C2.12–2.28139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TEMCD06AV41+TDR+TSTATAHRI reference: 21811245616.008.10132002.27EPA 4575553 →
5PX*D010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811245116.008.10133002.22EPA 4575555 →
5PX*D010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21811244916.008.10133002.22EPA 4575557 →
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811243216.008.10134002.20EPA 4575561 →
5PX*C009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21811243116.008.10132002.20EPA 4575562 →
5PX*C009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21811242516.008.10133002.18EPA 4575567 →
5PX*C009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21811242316.008.10133002.18EPA 4575568 →
5PX*C009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21811242116.008.10132002.20EPA 4575570 →
5TEMCD07AV51+TDR+TSTATAHRI reference: 21815945516.008.10131002.28EPA 4576546 →
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21815933216.008.00134002.19EPA 4576602 →
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21815933116.008.00134002.19EPA 4576603 →
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839610116.008.10135002.17EPA 4599271 →
5PX*B006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21839600916.008.00131002.19EPA 4599298 →
5TXCD008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21811249715.508.10133002.21EPA 4575539 →
5TXCD008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811249615.508.10133002.21EPA 4575540 →
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21811248615.508.10134002.18EPA 4575546 →
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21811248515.508.10134002.18EPA 4575547 →
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21811248415.508.10134002.18EPA 4575548 →
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21811248315.508.10134002.18EPA 4575549 →
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21811248215.508.10134002.20EPA 4575550 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →