Trane / AIR-SOURCE HEAT PUMP

5TWX6030A1

16 Single-Stage Heat Pump with WeatherGuard Top

139 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,200–29,600BTU/h

Each efficiency range summarizes published EPA records for 5TWX6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 139 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16139 / 139
EER2 · BTU/Wh11.7–12139 / 139
HSPF2 · BTU/Wh7.8–8.1139 / 139
Cooling capacity · BTU/h27,200–29,600139 / 139
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800139 / 139
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700139 / 139
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800139 / 139
COP at 5°F / −15°C2.12–2.28139 / 139
Equipment / loop typeHP - Split System139 / 139
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)139 / 139
Compressor stagingSingle stage139 / 139
Connected capabilityNo139 / 139

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21811012816.008.00131002.21EPA 4575008
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21811010716.008.10133002.19EPA 4575011
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21811010616.008.00132002.19EPA 4575012
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811010516.008.10134002.18EPA 4575013
5PX*C007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21811010416.008.00131002.20EPA 4575014
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21811008916.008.00133002.20EPA 4575018
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21811004116.008.00131002.21EPA 4575029
5TXCD008AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21811023416.008.00131002.21EPA 4575096
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811022916.008.10134002.18EPA 4575098
5TAMXD06AV41+TSTATAHRI reference: 21811013516.008.00133002.18EPA 4575105
5TAMXD05AV41+TSTATAHRI reference: 21811013416.008.10134002.19EPA 4575106
5TEMCD05AV41+TDR+TSTATAHRI reference: 21811014716.008.10132002.26EPA 4575111
5TEMCD04AV31+TDR+TSTATAHRI reference: 21811014616.008.10132002.26EPA 4575112
5TXCD010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21811250016.008.10133002.22EPA 4575537
5TXCD010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811249916.008.10133002.22EPA 4575538
5TXCC009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21811249316.008.10133002.18EPA 4575541
5TXCC009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21811249116.008.10133002.18EPA 4575542
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21811248916.008.10132002.20EPA 4575543
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21811248816.008.10132002.20EPA 4575544
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811248716.008.10134002.20EPA 4575545

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.