Trane / AIR-SOURCE HEAT PUMP

5TWX5042A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 8

231 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity38,000–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5231 / 231
EER2 · BTU/Wh11.7–12231 / 231
HSPF2 · BTU/Wh7.8–8.5231 / 231
Cooling capacity · BTU/h38,000–41,500231 / 231
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,000231 / 231
Heating capacity at 17°F / −8.3°C · BTU/h25,000–26,200231 / 231
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000231 / 231
COP at 5°F / −15°C2–2.3231 / 231
Equipment / loop typeHP - Split System231 / 231
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)231 / 231
Compressor stagingSingle stage231 / 231
Connected capabilityNo231 / 231

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21418276915.507.80192002.10EPA 3424382
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21418277115.507.80192002.10EPA 3424383
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDAAHRI reference: 21418277515.508.00194002.10EPA 3424385
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PCAAHRI reference: 21418278015.508.00194002.10EPA 3424386
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21418278215.507.80193002.10EPA 3424387
5TXCB006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21418278615.507.80193002.10EPA 3424388
5TXCB006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21418279015.508.00193002.10EPA 3424389
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21418282015.507.80192002.10EPA 3424401
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21418282315.507.80192002.10EPA 3424403
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21418284315.508.00194002.10EPA 3424404
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5PSBAHRI reference: 21418284515.508.10192002.10EPA 3424405
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21418284715.508.00193002.10EPA 3424544
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21418284915.508.00193002.10EPA 3424545
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21418285115.508.00194002.10EPA 3424546
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21418285315.508.00194002.10EPA 3424547
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21418285515.508.00193002.10EPA 3424548
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21418285715.508.00193002.10EPA 3424549
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21418286115.508.00194002.10EPA 3424550
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21418286315.508.10192002.10EPA 3424551
5TXCC007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21418287415.508.10192002.10EPA 3424554

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →