SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity38,000–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5231 / 231
EER2 · BTU/Wh11.7–12231 / 231
HSPF2 · BTU/Wh7.8–8.5231 / 231
Cooling capacity · BTU/h38,000–41,500231 / 231
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,000231 / 231
Heating capacity at 17°F / −8.3°C · BTU/h25,000–26,200231 / 231
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000231 / 231
COP at 5°F / −15°C2–2.3231 / 231
Equipment / loop typeHP - Split System231 / 231
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)231 / 231
Compressor stagingSingle stage231 / 231
Connected capabilityNo231 / 231

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*DD10AS3+TSTAT+P0V0D000M50SDAHRI reference: 21568740016.008.10191002.10EPA 3652169 →
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21568740316.008.10193002.10EPA 3652172 →
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21568740416.008.10193002.10EPA 3652173 →
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21568740616.008.10193002.10EPA 3652174 →
5PX*DD10AS3+TSTAT+ furnace: S9V2D120D5PSCAHRI reference: 21568740716.008.10192002.10EPA 3652175 →
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583169216.008.10192002.10EPA 3737741 →
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583169316.008.10194002.10EPA 3737742 →
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583169416.008.10193002.10EPA 3737743 →
5PX*C009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583169516.008.10192002.10EPA 3737744 →
5PX*DD10AS3+TSTAT+ furnace: S9V2D120D5VSBAHRI reference: 21583169916.008.10191002.10EPA 3737745 →
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583170516.008.10192002.10EPA 3737746 →
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583170616.008.10193002.10EPA 3737747 →
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583170716.008.10193002.10EPA 3737748 →
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583170816.008.10192002.10EPA 3737749 →
5TEMCD04AV31+TDR+TSTATAHRI reference: 21586397916.008.10189002.20EPA 3737779 →
5TEMCD05AV41+TDR+TSTATAHRI reference: 21586398016.008.10189002.20EPA 3737781 →
5TAM5D06AC41+TSTATAHRI reference: 21602198016.008.10191002.10EPA 3845939 →
5TAM5D07AC51+TSTATAHRI reference: 21602198116.008.10192002.10EPA 3845940 →
5TXCD008AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21836379116.008.10194002.10EPA 4587074 →
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21836378916.008.10193002.10EPA 4587075 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.