Trane / AIR-SOURCE HEAT PUMP

5TWX5042A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 11

231 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity38,000–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5231 / 231
EER2 · BTU/Wh11.7–12231 / 231
HSPF2 · BTU/Wh7.8–8.5231 / 231
Cooling capacity · BTU/h38,000–41,500231 / 231
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,000231 / 231
Heating capacity at 17°F / −8.3°C · BTU/h25,000–26,200231 / 231
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000231 / 231
COP at 5°F / −15°C2–2.3231 / 231
Equipment / loop typeHP - Split System231 / 231
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)231 / 231
Compressor stagingSingle stage231 / 231
Connected capabilityNo231 / 231

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21418276515.208.00193002.10EPA 3424381
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21418276715.208.00193002.10EPA 3424384
5TXCB006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21418279815.208.10192002.10EPA 3424390
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21418279615.208.10192002.10EPA 3424391
5TXCB006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21418280015.208.10192002.10EPA 3424392
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21418280415.208.10196002.00EPA 3424393
5TXCB006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21418280215.208.10192002.10EPA 3424394
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSAAHRI reference: 21418280615.208.10196002.00EPA 3424395
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4PSCAHRI reference: 21418280815.208.10195002.10EPA 3424396
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4PSBAHRI reference: 21418281015.208.10193002.10EPA 3424397
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21418281415.207.80194002.10EPA 3424398
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4PSBAHRI reference: 21418281615.208.10193002.10EPA 3424399
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21418281815.208.00193002.10EPA 3424400
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21418282515.208.00193002.10EPA 3424402
5TXCC007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21418286515.208.10193002.10EPA 3424552
5TXCC007AS3+TSTAT+ furnace: L9X1C100U5VSAAHRI reference: 21418287015.207.80195002.10EPA 3424553
5TXCC007AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21418288415.208.10193002.10EPA 3424559
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21568723315.208.10194002.10EPA 3651109
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21568721915.208.10194002.10EPA 3651133
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21568722015.208.10194002.10EPA 3651134

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →