Trane / AIR-SOURCE HEAT PUMP

5TWX5042A1

15 Single-Stage Heat Pump with WeatherGuard Top · source records, page 10

231 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity38,000–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWX5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5231 / 231
EER2 · BTU/Wh11.7–12231 / 231
HSPF2 · BTU/Wh7.8–8.5231 / 231
Cooling capacity · BTU/h38,000–41,500231 / 231
Heating capacity at 47°F / 8.3°C · BTU/h38,500–40,000231 / 231
Heating capacity at 17°F / −8.3°C · BTU/h25,000–26,200231 / 231
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000231 / 231
COP at 5°F / −15°C2–2.3231 / 231
Equipment / loop typeHP - Split System231 / 231
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)231 / 231
Compressor stagingSingle stage231 / 231
Connected capabilityNo231 / 231

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4PSCAHRI reference: 21418281215.508.10193002.10EPA 3549670
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21418289815.507.80194002.10EPA 3549671
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21418290215.507.80194002.10EPA 3549672
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21418290815.508.10194002.10EPA 3549673
5PX*C005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21568725815.508.00194002.10EPA 3651114
5TXCC009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21568744815.508.10192002.10EPA 3651137
5TXCC009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21568745015.508.10192002.10EPA 3651139
5TEM6D05AV41+TDR+TSTATAHRI reference: 21561098715.508.10192002.20EPA 3651489
5PX*C005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21568727715.508.00192002.10EPA 3652060
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21568729015.508.10196002.10EPA 3652068
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21568728915.508.10196002.10EPA 3652069
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21568729115.508.00193002.10EPA 3652070
5PX*C007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21568729215.508.00193002.10EPA 3652072
5PX*C009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21568731915.508.10192002.10EPA 3652094
5PX*C009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21568732115.508.10192002.10EPA 3652096
5PX*DD10AS3+TSTAT+ furnace: *DHMD120CCV5AHRI reference: 21568739815.508.10192002.10EPA 3652168
5PX*DD10AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21568740115.508.10191002.10EPA 3652170
5PX*DD10AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21568740215.508.10191002.10EPA 3652171
5PX*DD10AS3+TSTAT+ furnace: S9X2D120D5PSBAHRI reference: 21568740815.508.10192002.10EPA 3652176
5PX*DD10AS3+TSTAT+ furnace: S9X1D120D5PSBAHRI reference: 21568740915.508.10192002.10EPA 3652177

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →