5TWV0X60A1
20 TruComfort Variable Speed Heat Pump · source records, page 3
66 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5TWV0X60A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 66 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18.2–19 | 66 / 66 |
| EER2 · BTU/Wh | 10–10.5 | 66 / 66 |
| HSPF2 · BTU/Wh | 9–9.4 | 66 / 66 |
| Cooling capacity · BTU/h | 51,500–54,000 | 66 / 66 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 52,500–54,000 | 66 / 66 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 47,000–48,000 | 66 / 66 |
| Heating capacity at 5°F / −15°C · BTU/h | 37,600–38,500 | 66 / 66 |
| COP at 5°F / −15°C | 2–2.1 | 66 / 66 |
| Equipment / loop type | HP - Split System | 66 / 66 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 66 / 66 |
| Compressor staging | Continuously variable | 66 / 66 |
| Connected capability | No | 66 / 66 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCC009AS3+ furnace: S9V2C100U5VSB+LRPCold climate designationAHRI reference: 216440518 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846618 → |
5TXCD010AS3+ furnace: S9V2C080U5VSB+LRPCold climate designationAHRI reference: 216440546 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846646 → |
5TXCD010AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 216440552 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846652 → |
5PX*D010AS3+ furnace: *UHMD120CCV5+LRPCold climate designationAHRI reference: 216571156 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3848743 → |
5PX*DD10AS3+ furnace: *DHMD120CCV5+LRPCold climate designationAHRI reference: 216571158 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3848745 → |
5TXCD010AS3+ furnace: *UHMD120CCV5+LRPCold climate designationAHRI reference: 216571170 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3848757 → |
5PX*DD10AS3+ furnace: S9V2C100D5PSC+LRPCold climate designationAHRI reference: 216440482 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846510 → |
5PX*DD10AS3+ furnace: S9V2C100D5VSB+LRPCold climate designationAHRI reference: 216440486 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846514 → |
5PX*DD10AS3+ furnace: S9V2D120D5PSC+LRPCold climate designationAHRI reference: 216440488 | 18.40 | 9.00 | 37800 | 2.00 | EPA 3846516 → |
5PX*DD10AS3+ furnace: S9V2D120D5VSB+LRPCold climate designationAHRI reference: 216440490 | 18.40 | 9.00 | 37800 | 2.00 | EPA 3846518 → |
5PX*CD09AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216453225 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846742 → |
5PX*CD09AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216453227 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846744 → |
5PX*D010AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216453237 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846754 → |
5PX*D010AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216453241 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846758 → |
5TXCC009AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216453257 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846774 → |
5TXCC009AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216453259 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846776 → |
5TXCD010AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216453269 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846786 → |
5TXCD010AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216453273 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846790 → |
5PX*C009AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216453221 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846878 → |
5PX*C009AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216453223 | 18.40 | 9.00 | 38000 | 2.00 | EPA 3846880 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →