5TWV0X60A1
20 TruComfort Variable Speed Heat Pump · source records, page 2
66 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5TWV0X60A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 66 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18.2–19 | 66 / 66 |
| EER2 · BTU/Wh | 10–10.5 | 66 / 66 |
| HSPF2 · BTU/Wh | 9–9.4 | 66 / 66 |
| Cooling capacity · BTU/h | 51,500–54,000 | 66 / 66 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 52,500–54,000 | 66 / 66 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 47,000–48,000 | 66 / 66 |
| Heating capacity at 5°F / −15°C · BTU/h | 37,600–38,500 | 66 / 66 |
| COP at 5°F / −15°C | 2–2.1 | 66 / 66 |
| Equipment / loop type | HP - Split System | 66 / 66 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 66 / 66 |
| Compressor staging | Continuously variable | 66 / 66 |
| Connected capability | No | 66 / 66 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCD010AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 216440548 | 18.80 | 9.00 | 38000 | 2.00 | EPA 3846648 → |
5PX*D010AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 216453239 | 18.80 | 9.40 | 38000 | 2.00 | EPA 3846756 → |
5PX*D010AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 216453243 | 18.80 | 9.40 | 38000 | 2.00 | EPA 3846760 → |
5TXCD010AS3+ furnace: S8V2D120M5PDBCold climate designationAHRI reference: 216453271 | 18.80 | 9.40 | 38000 | 2.00 | EPA 3846788 → |
5TXCD010AS3+ furnace: S8V2D120M5PCBCold climate designationAHRI reference: 216453275 | 18.80 | 9.40 | 38000 | 2.00 | EPA 3846792 → |
5PX*C009AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 216440426 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846454 → |
5PX*C009AS3+ furnace: L8V1C100U5VSB+LRPCold climate designationAHRI reference: 216440428 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846456 → |
5PX*C009AS3+ furnace: S9V2C080U5VSB+LRPCold climate designationAHRI reference: 216440430 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846458 → |
5PX*C009AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 216440432 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846460 → |
5PX*C009AS3+ furnace: S9V2C100U5VSB+LRPCold climate designationAHRI reference: 216440434 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846462 → |
5PX*CD09AS3+ furnace: S9V2C100D5VSB+LRPCold climate designationAHRI reference: 216440440 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846468 → |
5PX*CD09AS3+ furnace: S9V2C100D5PSC+LRPCold climate designationAHRI reference: 216440442 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846470 → |
5PX*D010AS3+ furnace: S9V2C080U5VSB+LRPCold climate designationAHRI reference: 216440470 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846498 → |
5PX*D010AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 216440476 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846504 → |
5PX*DD10AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 216440480 | 18.60 | 9.00 | 37600 | 2.00 | EPA 3846508 → |
5PX*DD10AS3+P0V0D000M50SD+LRPCold climate designationAHRI reference: 216440484 | 18.60 | 9.00 | 37600 | 2.00 | EPA 3846512 → |
5TXCC009AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 216440510 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846610 → |
5TXCC009AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 216440512 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846611 → |
5TXCC009AS3+ furnace: S9V2C080U5VSB+LRPCold climate designationAHRI reference: 216440514 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846614 → |
5TXCC009AS3+ furnace: L8V1C100U5VSB+LRPCold climate designationAHRI reference: 216440516 | 18.60 | 9.00 | 38000 | 2.00 | EPA 3846616 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →