Each efficiency range summarizes published EPA records for 5TWV0X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 112 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19.2–21 | 112 / 112 |
| EER2 · BTU/Wh | 12–13 | 112 / 112 |
| HSPF2 · BTU/Wh | 9.4–10.5 | 112 / 112 |
| Cooling capacity · BTU/h | 34,600–36,200 | 112 / 112 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,600–33,200 | 112 / 112 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,400–31,600 | 112 / 112 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–25,400 | 112 / 112 |
| COP at 5°F / −15°C | 2.1–2.24 | 112 / 112 |
| Equipment / loop type | HP - Split System | 112 / 112 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 112 / 112 |
| Compressor staging | Continuously variable | 112 / 112 |
| Connected capability | No | 112 / 112 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCC009AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 216440220 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846320 → |
5TXCC009AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 216440222 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846322 → |
5TXCC009AS3+ furnace: S9V2C100U4VSB+LRPCold climate designationAHRI reference: 216440224 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846324 → |
5TXCC009AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 216440226 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846326 → |
5PX*C009AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 216570994 | 20.00 | 9.40 | 24600 | 2.20 | EPA 3848460 → |
5PX*C009AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 216570996 | 20.00 | 9.40 | 24600 | 2.20 | EPA 3848462 → |
5PX*C009AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216570998 | 20.00 | 9.70 | 24800 | 2.20 | EPA 3848464 → |
5PX*C009AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216571000 | 20.00 | 9.70 | 24800 | 2.20 | EPA 3848466 → |
5PX*CD09AS3+ furnace: *DHMC100CCV4+LRPCold climate designationAHRI reference: 216571008 | 20.00 | 9.70 | 24400 | 2.10 | EPA 3848474 → |
5PX*CD09AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 216571010 | 20.00 | 9.40 | 24600 | 2.10 | EPA 3848476 → |
5PX*CD09AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 216571012 | 20.00 | 9.40 | 24600 | 2.10 | EPA 3848478 → |
5PX*CD09AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216571014 | 20.00 | 9.40 | 24600 | 2.10 | EPA 3848480 → |
5PX*CD09AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216571016 | 20.00 | 9.40 | 24600 | 2.10 | EPA 3848482 → |
5TXCC009AS3+ furnace: S8V2C100M5PCBCold climate designationAHRI reference: 216571076 | 20.00 | 9.70 | 24800 | 2.20 | EPA 3848501 → |
5TXCC009AS3+ furnace: S8V2C080M5PDBCold climate designationAHRI reference: 216571068 | 20.00 | 9.40 | 24600 | 2.20 | EPA 3848606 → |
5TXCC009AS3+ furnace: S8V2C080M5PCBCold climate designationAHRI reference: 216571070 | 20.00 | 9.40 | 24600 | 2.20 | EPA 3848608 → |
5TXCC009AS3+ furnace: S8V2C100M5PDBCold climate designationAHRI reference: 216571072 | 20.00 | 9.70 | 24800 | 2.20 | EPA 3848610 → |
5PX*C009AS3+ furnace: S9V2B080D4PSC+LRPCold climate designationAHRI reference: 217179373 | 20.00 | 9.50 | 24800 | 2.10 | EPA 4010385 → |
5PX*C009AS3+ furnace: S9V2B080D4VSB+LRPCold climate designationAHRI reference: 217179375 | 20.00 | 9.50 | 24800 | 2.10 | EPA 4010386 → |
5PX*C009AS3+ furnace: S9V2B080U4PSC+LRPCold climate designationAHRI reference: 217179377 | 20.00 | 9.50 | 24800 | 2.10 | EPA 4010389 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.