5TWV0X36A1
20 TruComfort Variable Speed Heat Pump · source records, page 3
112 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5TWV0X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 112 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19.2–21 | 112 / 112 |
| EER2 · BTU/Wh | 12–13 | 112 / 112 |
| HSPF2 · BTU/Wh | 9.4–10.5 | 112 / 112 |
| Cooling capacity · BTU/h | 34,600–36,200 | 112 / 112 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,600–33,200 | 112 / 112 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,400–31,600 | 112 / 112 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–25,400 | 112 / 112 |
| COP at 5°F / −15°C | 2.1–2.24 | 112 / 112 |
| Equipment / loop type | HP - Split System | 112 / 112 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 112 / 112 |
| Compressor staging | Continuously variable | 112 / 112 |
| Connected capability | No | 112 / 112 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TXCC009AS3+ furnace: S8V2B080M4PCBCold climate designationAHRI reference: 217179457 | 20.20 | 9.70 | 24800 | 2.10 | EPA 4010479 → |
5PX*C009AS3+P0V0B000M40SD+LRPCold climate designationAHRI reference: 217179591 | 20.20 | 9.70 | 24400 | 2.20 | EPA 4010613 → |
5TXCC009AS3+P0V0B000M40SD+LRPCold climate designationAHRI reference: 217179595 | 20.20 | 9.70 | 24400 | 2.20 | EPA 4010617 → |
5TXCC009AS3+ furnace: S9V2B060U3VSB+VCKITCold climate designationAHRI reference: 218036367 | 20.20 | 9.70 | 24800 | 2.10 | EPA 4569296 → |
5TXCC009AS3+ furnace: S9V2B040U3VSB+VCKITCold climate designationAHRI reference: 218036365 | 20.20 | 10.00 | 24800 | 2.10 | EPA 4569298 → |
5TXCC009AS3+ furnace: S9V2B060U4VSB+VCKITCold climate designationAHRI reference: 218036363 | 20.20 | 9.70 | 24800 | 2.10 | EPA 4569300 → |
5PX*C009AS3+ furnace: S9V2B060U4VSB+VCKITCold climate designationAHRI reference: 218036343 | 20.20 | 9.70 | 24800 | 2.10 | EPA 4569320 → |
5PX*C009AS3+ furnace: S9V2B060U3VSB+VCKITCold climate designationAHRI reference: 218036333 | 20.20 | 9.70 | 24800 | 2.10 | EPA 4569330 → |
5PX*C009AS3+ furnace: S9V2C100U5PSC+LRPCold climate designationAHRI reference: 216440088 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846188 → |
5PX*C009AS3+ furnace: S9V2C080U5PSC+LRPCold climate designationAHRI reference: 216440090 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846190 → |
5PX*C009AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 216440092 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846192 → |
5PX*C009AS3+ furnace: S9V2C100U5VSB+LRPCold climate designationAHRI reference: 216440096 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846196 → |
5PX*C009AS3+ furnace: S9V2C100U4VSB+LRPCold climate designationAHRI reference: 216440098 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846198 → |
5PX*CD09AS3+P0V0C000M50SD+LRPCold climate designationAHRI reference: 216440100 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846200 → |
5PX*CD09AS3+ furnace: S9V2C100D4VSB+LRPCold climate designationAHRI reference: 216440102 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846202 → |
5PX*CD09AS3+ furnace: S9V2C100D5VSB+LRPCold climate designationAHRI reference: 216440104 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846203 → |
5PX*CD09AS3+ furnace: S9V2C100D5PSC+LRPCold climate designationAHRI reference: 216440106 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846206 → |
5TEMCD05AV41+TDRCold climate designationAHRI reference: 216440118 | 20.00 | 10.50 | 24600 | 2.20 | EPA 3846218 → |
5TXCC009AS3+ furnace: S9V2C100U5VSB+LRPCold climate designationAHRI reference: 216440216 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846316 → |
5TXCC009AS3+ furnace: S9V2C080U5VSB+LRPCold climate designationAHRI reference: 216440218 | 20.00 | 9.40 | 23800 | 2.10 | EPA 3846318 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →