Trane / AIR-SOURCE HEAT PUMP

5TWR7048A1

17 Multi-Speed Heat Pump · source records, page 4

231 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.5–9.4BTU/Wh
Cooling capacity43,000–44,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR7048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1231 / 231
EER2 · BTU/Wh11.2–12.5231 / 231
HSPF2 · BTU/Wh8.5–9.4231 / 231
Cooling capacity · BTU/h43,000–44,500231 / 231
Heating capacity at 47°F / 8.3°C · BTU/h43,500–46,000231 / 231
Heating capacity at 17°F / −8.3°C · BTU/h28,800–41,000231 / 231
Heating capacity at 5°F / −15°C · BTU/h31,800–33,800231 / 231
COP at 5°F / −15°C2.1–2.26231 / 231
Equipment / loop typeHP - Split System231 / 231
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)231 / 231
Compressor stagingTwo-stage231 / 231
Connected capabilityNo231 / 231

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD09AS3+ furnace: S8X2C100M5PTCAHRI reference: 21676477517.108.70322002.10EPA 3981111
5PX*D008AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676478117.109.00330002.20EPA 3981114
5PX*CD09AS3+ furnace: S8X1C080M5PTCAHRI reference: 21676477717.108.70320002.10EPA 3981115
5PX*D008AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676478517.109.00330002.20EPA 3981117
5PX*D008AS3+ furnace: S8X2D120M5PTCAHRI reference: 21676478717.109.00328002.20EPA 3981118
5PX*D010AS3+ furnace: S8X2C100M5PTCAHRI reference: 21676479317.109.00322002.20EPA 3981119
5PX*D008AS3+ furnace: S8X1C100M5PTCCold climate designationAHRI reference: 21676478917.109.00330002.20EPA 3981123
5PX*D008AS3+ furnace: S8X1D120M5PTCAHRI reference: 21676479117.109.00328002.20EPA 3981124
5PX*D010AS3+ furnace: S8X2C100M5PSCAHRI reference: 21676479717.109.00322002.20EPA 3981126
5PX*D010AS3+ furnace: S8X2C080M5PSCAHRI reference: 21676479917.109.00322002.20EPA 3981128
5PX*D010AS3+ furnace: S8X2C080M5PTCAHRI reference: 21676479517.109.00322002.20EPA 3981129
5PX*D010AS3+ furnace: S8X2D120M5PSCAHRI reference: 21676480117.109.00324002.20EPA 3981130
5PX*D010AS3+ furnace: S8X1D120M5PTCAHRI reference: 21676480317.109.00324002.20EPA 3981134
5PX*D010AS3+ furnace: S8X1C100M5PTCAHRI reference: 21676480717.109.00322002.20EPA 3981140
5PX*D010AS3+ furnace: S8X2D120M5PTCAHRI reference: 21676480517.109.00324002.20EPA 3981141
5PX*D010AS3+ furnace: S8X1C080M5PTCAHRI reference: 21676480917.109.00322002.20EPA 3981142
5PX*DD10AS3+ furnace: S8X2C080M5PTCAHRI reference: 21676481117.109.00326002.10EPA 3981143
5PX*DD10AS3+ furnace: S8X2D120M5PSCAHRI reference: 21676482117.109.00326002.20EPA 3981146
5PX*DD10AS3+ furnace: S8X2C080M5PSCAHRI reference: 21676481317.109.00326002.10EPA 3981147
5PX*DD10AS3+ furnace: S8X1C080M5PTCAHRI reference: 21676481717.109.00326002.10EPA 3981148

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →