Trane / AIR-SOURCE HEAT PUMP

5TWR7048A1

17 Multi-Speed Heat Pump · source records, page 3

231 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.5–9.4BTU/Wh
Cooling capacity43,000–44,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR7048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 231 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1231 / 231
EER2 · BTU/Wh11.2–12.5231 / 231
HSPF2 · BTU/Wh8.5–9.4231 / 231
Cooling capacity · BTU/h43,000–44,500231 / 231
Heating capacity at 47°F / 8.3°C · BTU/h43,500–46,000231 / 231
Heating capacity at 17°F / −8.3°C · BTU/h28,800–41,000231 / 231
Heating capacity at 5°F / −15°C · BTU/h31,800–33,800231 / 231
COP at 5°F / −15°C2.1–2.26231 / 231
Equipment / loop typeHP - Split System231 / 231
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)231 / 231
Compressor stagingTwo-stage231 / 231
Connected capabilityNo231 / 231

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+ furnace: *UHMC100CCV4AHRI reference: 21676401717.109.00320002.20EPA 3980166 →
5TXCD010AS3+ furnace: S9V2D120U5PSCAHRI reference: 21676402317.109.00320002.20EPA 3980167 →
5TXCD010AS3+ furnace: *UHMD120CCV5AHRI reference: 21676401917.109.00320002.20EPA 3980169 →
5TXCD010AS3+ furnace: S8X1D120M5PSCAHRI reference: 21676401517.109.00324002.20EPA 3980172 →
5TXCD010AS3+ furnace: S9V2D120U5VSBAHRI reference: 21676402117.109.00320002.20EPA 3980173 →
5TXCD010AS3+ furnace: L8V1C100U5VSBAHRI reference: 21676402717.109.00320002.20EPA 3980177 →
5TXCD010AS3+ furnace: S9V2C080U5PSCAHRI reference: 21676402917.109.00320002.20EPA 3980180 →
5TXCD010AS3+ furnace: S9V2C100U4VSBAHRI reference: 21676403117.109.00320002.20EPA 3980181 →
5TXCD010AS3+ furnace: S9V2C100U5PSCAHRI reference: 21676402517.109.00320002.20EPA 3980182 →
5PX*C009AS3+ furnace: S8X2C080M5PTCAHRI reference: 21676475717.109.00322002.20EPA 3981087 →
5PX*C009AS3+ furnace: S8X2C100M5PTCCold climate designationAHRI reference: 21676475917.109.00322002.20EPA 3981089 →
5PX*C009AS3+ furnace: S8X1C080M5PTCAHRI reference: 21676476517.109.00322002.20EPA 3981093 →
5PX*C009AS3+ furnace: S8X2C080M5PSCAHRI reference: 21676476117.109.00322002.20EPA 3981095 →
5PX*C009AS3+ furnace: S8X2C100M5PSCCold climate designationAHRI reference: 21676476317.109.00322002.20EPA 3981098 →
5PX*CD09AS3+ furnace: S8X2C100M5PSCAHRI reference: 21676477317.108.70322002.10EPA 3981099 →
5PX*C009AS3+ furnace: S8X1C100M5PTCCold climate designationAHRI reference: 21676476717.109.00322002.20EPA 3981102 →
5PX*CD09AS3+ furnace: S8X2C080M5PTCAHRI reference: 21676476917.108.70320002.10EPA 3981105 →
5PX*CD09AS3+ furnace: S8X2C080M5PSCAHRI reference: 21676477117.108.70320002.10EPA 3981106 →
5PX*CD09AS3+ furnace: S8X1C100M5PTCAHRI reference: 21676477917.108.70322002.10EPA 3981107 →
5PX*D008AS3+ furnace: S8X2D120M5PSCAHRI reference: 21676478317.109.00328002.20EPA 3981109 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →