Trane / AIR-SOURCE HEAT PUMP

5TWR6048A1

16 Single-Stage Heat Pump · source records, page 6

127 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–46,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR6048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16127 / 127
EER2 · BTU/Wh11.5–12127 / 127
HSPF2 · BTU/Wh7.8–8.5127 / 127
Cooling capacity · BTU/h43,000–46,500127 / 127
Heating capacity at 47°F / 8.3°C · BTU/h41,500–43,500127 / 127
Heating capacity at 17°F / −8.3°C · BTU/h28,200–29,200127 / 127
Heating capacity at 5°F / −15°C · BTU/h21,800–22,600127 / 127
COP at 5°F / −15°C2.1–2.3127 / 127
Equipment / loop typeHP - Split System127 / 127
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)127 / 127
Compressor stagingSingle stage127 / 127
Connected capabilityNo127 / 127

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*DD10AS3+TSTAT+ furnace: S9X1D120D5PSBAHRI reference: 21839576015.208.10220002.13EPA 4599347
5PX*D010AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21839575415.208.10224002.15EPA 4599351
5PX*D010AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21839575215.208.00222002.19EPA 4599353
5PX*D010AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21839575015.208.00222002.19EPA 4599355
5PX*D010AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21839574615.208.10224002.17EPA 4599359
5PX*D010AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21839574015.208.00220002.18EPA 4599365
5PX*D010AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21839573815.208.10222002.16EPA 4599367
5PX*D010AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21839573615.208.00220002.18EPA 4599369
5PX*D010AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21839573415.208.10222002.16EPA 4599371
5PX*D008AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21839573015.208.00224002.10EPA 4599373
5PX*D008AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21839572815.208.00226002.10EPA 4599375
5PX*D008AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21839572615.208.00226002.10EPA 4599377
5PX*D008AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21839572415.208.00226002.10EPA 4599379
5PX*D008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21839572015.208.10222002.13EPA 4599381
5PX*D008AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21839571615.208.00224002.10EPA 4599383
5PX*D008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21839571415.208.10222002.13EPA 4599385
5PX*D008AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21839571215.208.00226002.10EPA 4599387
5PX*D008AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21839571015.208.00226002.10EPA 4599389
5PX*D008AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21839570815.208.00226002.10EPA 4599391
5PX*D008AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21839570615.208.10226002.10EPA 4599393

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →