Trane / AIR-SOURCE HEAT PUMP

5TWR6048A1

16 Single-Stage Heat Pump · source records, page 5

127 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity43,000–46,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR6048A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 127 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16127 / 127
EER2 · BTU/Wh11.5–12127 / 127
HSPF2 · BTU/Wh7.8–8.5127 / 127
Cooling capacity · BTU/h43,000–46,500127 / 127
Heating capacity at 47°F / 8.3°C · BTU/h41,500–43,500127 / 127
Heating capacity at 17°F / −8.3°C · BTU/h28,200–29,200127 / 127
Heating capacity at 5°F / −15°C · BTU/h21,800–22,600127 / 127
COP at 5°F / −15°C2.1–2.3127 / 127
Equipment / loop typeHP - Split System127 / 127
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)127 / 127
Compressor stagingSingle stage127 / 127
Connected capabilityNo127 / 127

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21839582615.208.10222002.16EPA 4599307
5TXCD008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21839582415.208.10222002.13EPA 4599309
5TXCD008AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21839582215.208.00224002.10EPA 4599311
5TXCD008AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21839581815.208.10226002.10EPA 4599313
5TXCD008AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21839581615.208.00226002.10EPA 4599315
5TXCD008AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21839581415.208.00226002.10EPA 4599317
5TXCD008AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21839581215.208.00226002.10EPA 4599319
5TXCD008AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21839581015.208.00226002.10EPA 4599321
5TXCD008AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21839580815.208.00226002.10EPA 4599323
5TXCD008AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21839580415.208.00224002.10EPA 4599325
5TXCD008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21839580215.208.10222002.13EPA 4599327
5TXCD008AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21839580015.208.00226002.10EPA 4599329
5TXCC009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21839579615.208.10220002.17EPA 4599331
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21839579415.208.00222002.20EPA 4599333
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21839579015.208.10222002.17EPA 4599335
5TXCC009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839578815.208.10222002.16EPA 4599337
5TXCC009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21839578615.207.80220002.18EPA 4599339
5TXCC009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21839578415.208.10220002.17EPA 4599341
5TXCC009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21839578215.207.80220002.18EPA 4599343
5PX*DD10AS3+TSTAT+ furnace: S9X2D120D5PSBAHRI reference: 21839576215.208.10220002.13EPA 4599345

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →