Trane / AIR-SOURCE HEAT PUMP

5TWR6030A1

16 Single-Stage Heat Pump · source records, page 5

143 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,000–29,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16143 / 143
EER2 · BTU/Wh11.7–12143 / 143
HSPF2 · BTU/Wh7.8–8.1143 / 143
Cooling capacity · BTU/h27,000–29,200143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700143 / 143
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800143 / 143
COP at 5°F / −15°C2.12–2.28143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)143 / 143
Compressor stagingSingle stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810685015.207.80133002.18EPA 4573811
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21810684415.207.80134002.18EPA 4573813
5TXCD010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811191715.208.10133002.22EPA 4575605
5TXCD010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21811191515.208.10133002.22EPA 4575607
5TXCD008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811191115.208.10133002.21EPA 4575609
5TXCD008AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21811190915.208.10133002.21EPA 4575611
5TXCC009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21811189515.208.10133002.20EPA 4575619
5TXCC009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21811189115.208.10133002.20EPA 4575623
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21811188715.208.00134002.20EPA 4575627
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21811188515.208.00134002.20EPA 4575629
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21811188315.208.10134002.19EPA 4575631
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21811188115.208.10134002.19EPA 4575633
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21811187915.208.10134002.19EPA 4575635
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21811187715.208.10134002.19EPA 4575637
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21811183715.208.10134002.17EPA 4575639
5PX*DD10AS3+TSTAT+ furnace: *DHMD120CCV5AHRI reference: 21811181915.208.00132002.17EPA 4575645
5PX*D010AS3+TSTAT+ furnace: S9X2D120U5PSBAHRI reference: 21811181515.208.10133002.22EPA 4575647
5PX*D010AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811181315.208.10133002.22EPA 4575649
5PX*D010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21811181115.208.10131002.23EPA 4575651
5PX*D008AS3+TSTAT+ furnace: S9X1D120U5PSBAHRI reference: 21811180715.208.10133002.21EPA 4575653

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →