Trane / AIR-SOURCE HEAT PUMP

5TWR6030A1

16 Single-Stage Heat Pump · source records, page 4

143 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,000–29,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16143 / 143
EER2 · BTU/Wh11.7–12143 / 143
HSPF2 · BTU/Wh7.8–8.1143 / 143
Cooling capacity · BTU/h27,000–29,200143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700143 / 143
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800143 / 143
COP at 5°F / −15°C2.12–2.28143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)143 / 143
Compressor stagingSingle stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD07AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810706615.208.10136002.13EPA 4573755
5PX*CD07AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21810706015.208.10136002.13EPA 4573757
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810698815.207.80134002.19EPA 4573771
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21810698615.207.80134002.19EPA 4573773
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21810698015.207.80134002.19EPA 4573775
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21810697415.207.80134002.19EPA 4573777
5PX*BD06AS3+TSTAT+ furnace: S9V2B040D3VSBAHRI reference: 21810697015.207.80132002.17EPA 4573779
5PX*BD06AS3+TSTAT+ furnace: S9V2B080D4VSBAHRI reference: 21810696815.207.80133002.16EPA 4573781
5PX*BD06AS3+TSTAT+ furnace: S9X1B060D3PSBAHRI reference: 21810696615.207.80133002.17EPA 4573783
5PX*BD06AS3+TSTAT+ furnace: S9X1B080D4PSBAHRI reference: 21810696215.207.80133002.17EPA 4573785
5PX*BD06AS3+TSTAT+ furnace: S9X2B060D3PSBAHRI reference: 21810696015.207.80133002.17EPA 4573787
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21810695215.207.80134002.19EPA 4573789
5PX*BD06AS3+TSTAT+ furnace: S9X2B080D4PSBAHRI reference: 21810694215.207.80133002.17EPA 4573793
5PX*BD06AS3+TSTAT+ furnace: *DHMB080CCV3AHRI reference: 21810694015.207.80133002.16EPA 4573795
5PX*BD06AS3+TSTAT+P0V0A000M30SDAHRI reference: 21810693815.207.80133002.16EPA 4573797
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21810693615.207.80134002.19EPA 4573799
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PCBAHRI reference: 21810693015.207.80133002.18EPA 4573801
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21810692815.207.80133002.18EPA 4573803
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21810687815.207.80133002.18EPA 4573805
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810685215.207.80134002.18EPA 4573809

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →