Trane / AIR-SOURCE HEAT PUMP

5TWR5036A1

15 Single-Stage Heat Pump · source records, page 6

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556839216.008.10177002.20EPA 3650592
5TXCC005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556633416.008.10172002.30EPA 3650673
5TXCC009AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21556637816.008.10170002.30EPA 3650711
5TXCC009AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21556638016.008.10172002.30EPA 3650713
5TXCC009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21556638416.008.10172002.30EPA 3650717
5TXCC009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21556638816.008.10172002.30EPA 3650721
5TXCC009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556639016.008.10171002.30EPA 3650723
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556639216.008.10171002.30EPA 3650725
5TXCC009AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21556639416.008.10173002.30EPA 3650727
5TXCC009AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21556639616.008.10173002.30EPA 3650729
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556639816.008.10174002.30EPA 3650731
5TXCC009AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556640016.008.10174002.30EPA 3650733
5TXCC009AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556640616.008.10172002.30EPA 3650773
5TXCC009AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21556640816.008.10174002.30EPA 3650776
5TXCC009AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21556641016.008.10174002.30EPA 3650777
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21556641216.008.10174002.30EPA 3650779
5TXCC009AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21556641416.008.10174002.30EPA 3650781
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21556641616.008.10174002.30EPA 3650783
5TXCC009AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21556641816.008.10174002.30EPA 3650785
5TXCC009AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21556642016.008.10173002.30EPA 3650787

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →