Trane / AIR-SOURCE HEAT PUMP

5TWR5036A1

15 Single-Stage Heat Pump · source records, page 5

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*D010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21556869616.008.50176002.30EPA 3650041
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21556869816.008.10172002.30EPA 3650043
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21556870016.008.10172002.30EPA 3650045
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21556870216.008.10172002.30EPA 3650047
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21556870416.008.10172002.30EPA 3650048
5PX*DD10AS3+TSTAT+ furnace: *DHMD120CCV5AHRI reference: 21556871016.008.10171002.30EPA 3650055
5PX*DD10AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21556871416.008.10174002.30EPA 3650057
5PX*DD10AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21556871616.008.10174002.30EPA 3650059
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556820216.008.10175002.30EPA 3650313
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21556821816.008.10173002.30EPA 3650330
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21556822016.008.10173002.30EPA 3650333
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21556822216.008.10174002.30EPA 3650334
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21556822416.008.10174002.30EPA 3650336
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21556823016.008.10173002.30EPA 3650342
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21556823216.008.10173002.30EPA 3650343
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21556823416.008.10174002.30EPA 3650346
5PX*B006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21556823616.008.10174002.30EPA 3650348
5PX*B006AS3+TSTAT+ furnace: S9V2B060U3VSBAHRI reference: 21556824216.008.10174002.30EPA 3650354
5PX*B006AS3+TSTAT+ furnace: S9V2B060U4PSCAHRI reference: 21556824416.008.10174002.30EPA 3650356
5PX*B006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21556818616.008.10173002.30EPA 3650406

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →