Trane / AIR-SOURCE HEAT PUMP

4TWV8X48A1

XV18 · XV18I · source records, page 9

207 published source records · source checked Sep 21, 2026

SEER2 range18BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity44,000–47,000BTU/h

Each efficiency range summarizes published EPA records for 4TWV8X48A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 207 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18207 / 207
EER2 · BTU/Wh11–12207 / 207
HSPF2 · BTU/Wh8–8.5207 / 207
Cooling capacity · BTU/h44,000–47,000207 / 207
Heating capacity at 47°F / 8.3°C · BTU/h41,000–46,000207 / 207
Heating capacity at 17°F / −8.3°C · BTU/h35,200–37,800207 / 207
Heating capacity at 5°F / −15°C · BTU/h27,400–29,400207 / 207
COP at 5°F / −15°C1.68–2207 / 207
Equipment / loop typeHP - Split System207 / 207
Refrigerant / source-reported GWPR-410A (GWP:2088)207 / 207
Compressor stagingContinuously variable207 / 207
Connected capabilityNo207 / 207

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*CD60BS3+ furnace: S8V2C080M5PDBAHRI reference: 21425338318.008.50284001.70EPA 3413084
4PX*CU60BS3+ furnace: S8V2C080M5PCBAHRI reference: 21425340118.008.50284001.80EPA 3413093
4PX*CU60BS3+ furnace: S8V2C100M5PCBAHRI reference: 21425340318.008.50286001.80EPA 3413095
4PX*CU60BS3+ furnace: S8V2C100M5PDBAHRI reference: 21425340518.008.50286001.80EPA 3413097
4PX*CU60BS3+ furnace: S8V2C080M5PDBAHRI reference: 21425340718.008.50284001.80EPA 3413100
4TXCC007DS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464006918.008.50288001.80EPA 3476853
4TXCC009DS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464007118.008.50286001.80EPA 3476855
4TXCD008DS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 21464007318.008.50280001.70EPA 3476857
4TXCD008DS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464007518.008.50280001.70EPA 3476859
4TXCD010DS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 21464007718.008.50276001.80EPA 3476860
4PX*CD60BS3+ furnace: S9V2C100D5PSC+RPAHRI reference: 21464002518.008.50284001.80EPA 3476861
4PX*CD60BS3+HORIZ-RT+ furnace: S9V2C080U5PSC+RPAHRI reference: 21464002718.008.50286001.70EPA 3476864
4TXCD010DS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464007918.008.50276001.80EPA 3476866
4PX*CD60BS3+HORIZ-RT+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464002918.008.50284001.80EPA 3476868
4PX*CU42BS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464003318.008.50288001.80EPA 3476871
4PX*CU60BS3+ furnace: S9V2C100U4VSB+RPAHRI reference: 21463893718.008.50290001.80EPA 3476940
4PX*DU60BS3+ furnace: S9V2C100U4VSB+RPAHRI reference: 21463894518.008.50278001.80EPA 3476944
4TXCC009DS3+ furnace: S9V2C100U4VSB+RPAHRI reference: 21463895718.008.50290001.80EPA 3476946
4TXCD010DS3+ furnace: S9V2C100U4VSB+RPAHRI reference: 21463896118.008.50278001.80EPA 3476948
4PX*CD60BS3+ furnace: S9V2C100D4VSB+RPAHRI reference: 21463892718.008.50288001.70EPA 3477022

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →