Trane / AIR-SOURCE HEAT PUMP

4TWV8X48A1

XV18 · XV18I · source records, page 10

207 published source records · source checked Sep 21, 2026

SEER2 range18BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity44,000–47,000BTU/h

Each efficiency range summarizes published EPA records for 4TWV8X48A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 207 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18207 / 207
EER2 · BTU/Wh11–12207 / 207
HSPF2 · BTU/Wh8–8.5207 / 207
Cooling capacity · BTU/h44,000–47,000207 / 207
Heating capacity at 47°F / 8.3°C · BTU/h41,000–46,000207 / 207
Heating capacity at 17°F / −8.3°C · BTU/h35,200–37,800207 / 207
Heating capacity at 5°F / −15°C · BTU/h27,400–29,400207 / 207
COP at 5°F / −15°C1.68–2207 / 207
Equipment / loop typeHP - Split System207 / 207
Refrigerant / source-reported GWPR-410A (GWP:2088)207 / 207
Compressor stagingContinuously variable207 / 207
Connected capabilityNo207 / 207

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*CU48BS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464003918.008.50288001.80EPA 3477104 →
4PX*CU60BS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 21464004118.008.50286001.80EPA 3477106 →
4PX*CU60BS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464004318.008.50286001.80EPA 3477107 →
4PX*DD60BS3+ furnace: S9V2C100D5PSC+RPAHRI reference: 21464004518.008.50276001.70EPA 3477110 →
4PX*DD60BS3+HORIZ-RT+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464004918.008.50276001.70EPA 3477112 →
4PX*DU48BS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 21464005118.008.50280001.70EPA 3477114 →
4PX*DU48BS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464005318.008.50280001.70EPA 3477116 →
4PX*DU60BS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 21464005518.008.50276001.80EPA 3477118 →
4PX*DU60BS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 21464005718.008.50276001.80EPA 3477121 →
4PX*DU48BS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 21582590318.008.50288001.83EPA 3799442 →
4PX*DU60BS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582590518.008.50284001.86EPA 3799444 →
4PX*DU60BS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 21582590718.008.50284001.86EPA 3799446 →
4TXCC009DS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 21582591318.008.50286001.86EPA 3799447 →
4TXCD010DS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582591718.008.50284001.86EPA 3799469 →
4PX*CD60BS3+ furnace: S9V2C100D5VSB+RPAHRI reference: 21582588518.008.50284001.79EPA 3799640 →
4PX*CU60BS3+ furnace: S9V2C080U5VSB+RPAHRI reference: 21582589518.008.50286001.85EPA 3799642 →
4PX*CU60BS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 21582589718.008.50286001.86EPA 3799644 →
4PX*BU48BS3+ furnace: S9V2B060U4PSC+RPAHRI reference: 21464001518.008.50292001.80EPA 4009490 →
4PX*BU48BS3+ furnace: S9V2B080U4PSC+RPAHRI reference: 21464001718.008.50294001.80EPA 4009491 →
4PX*CU48BS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 21464003718.008.50290001.80EPA 4009492 →