Heating performance & equipment details
Ranges include the 210 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.5–20.5 | 210 / 210 |
| EER2 · BTU/Wh | 11.2–12.7 | 210 / 210 |
| HSPF2 · BTU/Wh | 8–8.7 | 210 / 210 |
| Cooling capacity · BTU/h | 32,200–36,000 | 210 / 210 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,800–35,400 | 209 / 210 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,400–29,000 | 210 / 210 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,000–22,400 | 188 / 210 |
| COP at 5°F / −15°C | 1.6–1.92 | 188 / 210 |
| Equipment / loop type | HP - Split System | 210 / 210 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 210 / 210 |
| Compressor staging | Continuously variable | 210 / 210 |
| Connected capability | No | 210 / 210 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4PX*BD42BS3+HORIZ-RT+ furnace: S9V2B060U4PSC+RPAHRI reference: 214639441 | 20.00 | 8.50 | — | — | EPA 3477276 → |
4PX*BD42BS3+HORIZ-RT+ furnace: S9V2B040U3PSC+RPAHRI reference: 214639443 | 20.00 | 8.50 | — | — | EPA 3477278 → |
4PX*CU42BS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 214639465 | 20.00 | 8.70 | — | — | EPA 3477295 → |
4PX*BD42BS3+ furnace: *DHMB080CCV3AHRI reference: 214250633 | 20.00 | 8.00 | 20000 | 1.70 | EPA 3549644 → |
4PX*BU36BS3+ furnace: *UHMB060CCV3AHRI reference: 214250637 | 20.00 | 8.20 | — | — | EPA 3549645 → |
4PX*BU36BS3+ furnace: *UHMB080CCV3AHRI reference: 214250635 | 20.00 | 8.50 | 20400 | 1.70 | EPA 3549646 → |
4PX*CD36BS3+ furnace: *DHMC100CCV4AHRI reference: 214250647 | 20.00 | 8.00 | 20800 | 1.60 | EPA 3549649 → |
4PX*BD36BS3+ furnace: S8V2B060M4PCBAHRI reference: 214252947 | 20.00 | 8.00 | 21000 | 1.60 | EPA 3549683 → |
4PX*BD36BS3+ furnace: S8V2B060M4PDBAHRI reference: 214252949 | 20.00 | 8.00 | 21000 | 1.60 | EPA 3549684 → |
4PX*BD36BS3+ furnace: S8V2B080M4PCBAHRI reference: 214252953 | 20.00 | 8.00 | 21000 | 1.60 | EPA 3549685 → |
4PX*BD36BS3+ furnace: S8V2B080M4PDBAHRI reference: 214252951 | 20.00 | 8.00 | 21000 | 1.60 | EPA 3549686 → |
4PX*BD42BS3+ furnace: S8V2B060M4PCBAHRI reference: 214252963 | 20.00 | 8.10 | 20800 | 1.70 | EPA 3549687 → |
4PX*BD42BS3+ furnace: S8V2B060M4PDBAHRI reference: 214252955 | 20.00 | 8.10 | 20800 | 1.70 | EPA 3549688 → |
4PX*BD42BS3+ furnace: S8V2B080M4PCBAHRI reference: 214252957 | 20.00 | 8.10 | 20800 | 1.70 | EPA 3549689 → |
4PX*BD42BS3+ furnace: S8V2B080M4PDBAHRI reference: 214252959 | 20.00 | 8.10 | 20800 | 1.70 | EPA 3549690 → |
4TXCB004DS3+ furnace: S9V2B060U4PSB+RPAHRI reference: 208185397 | 19.50 | 8.50 | 20200 | 1.70 | EPA 2472647 → |
TAMXB0C36V31AHRI reference: 210929563 | 19.50 | 8.70 | 20000 | 1.85 | EPA 2472781 → |
4PX*CU42BS3+ furnace: S8V2C080M5PCAAHRI reference: 210691825 | 19.50 | 8.50 | 20400 | 1.81 | EPA 2472908 → |
4PX*BU36BS3+ furnace: S8V2B060M4PCAAHRI reference: 210691813 | 19.50 | 8.50 | 20800 | 1.78 | EPA 2472911 → |
4TXCB004DS3+ furnace: S8V2B060M4PCAAHRI reference: 210691829 | 19.50 | 8.50 | 20800 | 1.78 | EPA 2472913 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →