Trane / AIR-SOURCE HEAT PUMP

4TWV0X36A1

XV20I · source records, page 5

210 published source records · source checked Sep 21, 2026

SEER2 range17.5–20.5BTU/Wh
HSPF2 range8–8.7BTU/Wh
Cooling capacity32,200–36,000BTU/h

Each efficiency range summarizes published EPA records for 4TWV0X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 210 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.5–20.5210 / 210
EER2 · BTU/Wh11.2–12.7210 / 210
HSPF2 · BTU/Wh8–8.7210 / 210
Cooling capacity · BTU/h32,200–36,000210 / 210
Heating capacity at 47°F / 8.3°C · BTU/h29,800–35,400209 / 210
Heating capacity at 17°F / −8.3°C · BTU/h24,400–29,000210 / 210
Heating capacity at 5°F / −15°C · BTU/h19,000–22,400188 / 210
COP at 5°F / −15°C1.6–1.92188 / 210
Equipment / loop typeHP - Split System210 / 210
Refrigerant / source-reported GWPR-410A (GWP:2088)210 / 210
Compressor stagingContinuously variable210 / 210
Connected capabilityNo210 / 210

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*CD42BS3+ furnace: S8V2C100M5PDBAHRI reference: 21425300320.008.20204001.70EPA 3412851 →
4PX*CD42BS3+ furnace: S8V2C080M5PCBAHRI reference: 21425300520.008.10202001.70EPA 3412853 →
4PX*CD42BS3+ furnace: S8V2C080M5PDBAHRI reference: 21425300120.008.10202001.70EPA 3412856 →
4PX*CU42BS3+ furnace: S8V2C100M5PCBAHRI reference: 21425301720.008.50206001.80EPA 3412865 →
4PX*CU42BS3+ furnace: S8V2C100M5PDBAHRI reference: 21425301920.008.50206001.80EPA 3412868 →
4PX*CU48BS3+ furnace: S8V2C080M5PCBAHRI reference: 21425302720.008.50204001.80EPA 3412876 →
4PX*CU48BS3+ furnace: S8V2C080M5PDBAHRI reference: 21425302920.008.50204001.80EPA 3412878 →
4PX*CD42BS3+ furnace: *DHMC100CCV4AHRI reference: 21425064920.008.20204001.70EPA 3412926 →
4PX*CU36BS3+ furnace: *UHMC100CCV4AHRI reference: 21425065120.008.50202001.80EPA 3412928 →
4TXCB004DS3+ furnace: *UHMB060CCV3AHRI reference: 21425065920.008.20204001.80EPA 3412951 →
4TXCC005DS3+ furnace: *UHMC100CCV4AHRI reference: 21425066520.008.50202001.80EPA 3412953 →
4TXCB004DS3+ furnace: *UHMB080CCV3AHRI reference: 21425065720.008.50204001.70EPA 3412954 →
4PX*BU36BS3+ furnace: S9V2B040U3VSB+RPAHRI reference: 21463880320.008.50——EPA 3476917 →
4PX*BU36BS3+ furnace: S9V2B080U4VSB+RPAHRI reference: 21463880520.008.50——EPA 3476919 →
4PX*BU36BS3+ furnace: S9V2B060U3VSB+RPAHRI reference: 21463880720.008.20——EPA 3476921 →
4TXCB004DS3+ furnace: S9V2B080U4VSB+RPAHRI reference: 21463882120.008.50——EPA 3476929 →
4TXCB004DS3+ furnace: S9V2B040U3VSB+RPAHRI reference: 21463882320.008.20——EPA 3476931 →
4PX*BD42BS3+ furnace: S9V2B080D4PSC+RPAHRI reference: 21463943520.008.50——EPA 3477270 →
4PX*BD42BS3+ furnace: S9V2B040D3PSC+RPAHRI reference: 21463943720.008.50——EPA 3477272 →
4PX*BD42BS3+HORIZ-RT+ furnace: S9V2B080U4PSC+RPAHRI reference: 21463943920.008.50——EPA 3477273 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →