RD18AY36AJVC
VANTIX · source records, page 3
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 192 / 192 |
| EER2 · BTU/Wh | 11.7–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 8.1–10 | 192 / 192 |
| Cooling capacity · BTU/h | 31,000–32,800 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–28,200 | 192 / 192 |
| COP at 5°F / −15°C | 1.9–2.2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | Yes | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY3621STANM+ furnace: S802V1005A21DZCold climate designationAHRI reference: 216891969 | 19.00 | 8.50 | 27400 | 2.00 | EPA 3994828 → |
TCFY3621STANM+ furnace: S951V0855A21M4Cold climate designationAHRI reference: 216891968 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994829 → |
TCFY3621STANM+ furnace: S801V0754A17DZCold climate designationAHRI reference: 216891974 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994832 → |
TCFY3621STANM+ furnace: S962V0855A21M4Cold climate designationAHRI reference: 216891973 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994833 → |
TCFY3621STANM+ furnace: S801V1004A17UHCold climate designationAHRI reference: 216891975 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994834 → |
TCFY3617STANM+ furnace: S802V0754A17UHCold climate designationAHRI reference: 216891976 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994835 → |
TCFY3617STANM+ furnace: S802V0754A17DZCold climate designationAHRI reference: 216891977 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994836 → |
TCFY3617STANM+ furnace: S801V0503A14DZCold climate designationAHRI reference: 216891979 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994837 → |
TCFY3621STANM+ furnace: S97MV0855A21DHCold climate designationAHRI reference: 216891980 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994839 → |
TCFY3621STANM+ furnace: S802V0754A17DZCold climate designationAHRI reference: 216891981 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994853 → |
TCFY3621STANM+ furnace: S951V1005A21UHCold climate designationAHRI reference: 216891983 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994855 → |
TCFY3621STANM+ furnace: S801V1005A21UHSCold climate designationAHRI reference: 216891989 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994861 → |
TCFY3621STANM+ furnace: S801V1005A21UHUCold climate designationAHRI reference: 216891990 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994862 → |
TCFY3621STANM+ furnace: S802V0754A17UHCold climate designationAHRI reference: 216891991 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994863 → |
TCFY3621STANM+ furnace: S97MV1005A21DHCold climate designationAHRI reference: 216891993 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994864 → |
TCFY3621STANM+ furnace: S951V0705A21UHUCold climate designationAHRI reference: 216891992 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994865 → |
TCFY3621STANM+ furnace: S802V0755A21UHCold climate designationAHRI reference: 216892002 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994875 → |
TCFY3617STANM+ furnace: S98MV0703A17UPCold climate designationAHRI reference: 216892005 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994880 → |
TCFY3621STANM+ furnace: S801V0755A21UHCold climate designationAHRI reference: 216892020 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994883 → |
TCFY3621STANM+ furnace: S98MV0855A21UPCold climate designationAHRI reference: 216892008 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994884 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →