RD18AY36AJVC
VANTIX · source records, page 2
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 192 / 192 |
| EER2 · BTU/Wh | 11.7–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 8.1–10 | 192 / 192 |
| Cooling capacity · BTU/h | 31,000–32,800 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–28,200 | 192 / 192 |
| COP at 5°F / −15°C | 1.9–2.2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | Yes | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY3621MTANM+ furnace: S802V0754A17DZCold climate designationAHRI reference: 216891907 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994760 → |
TCFY3621MTANM+ furnace: S801V1004A17UHCold climate designationAHRI reference: 216891909 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994761 → |
TCFY3621MTANM+ furnace: S97MV0855A21DHCold climate designationAHRI reference: 216891913 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994765 → |
TCFY3621MTANM+ furnace: S98MV0855A21UPCold climate designationAHRI reference: 216891916 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994767 → |
TCFY3621MTANM+ furnace: S802V0755A21UHCold climate designationAHRI reference: 216891917 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994768 → |
TCFY3621MTANM+ furnace: S801V0754A17UHCold climate designationAHRI reference: 216891918 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994769 → |
TCFY3621MTANM+ furnace: S802V1004A17UHCold climate designationAHRI reference: 216891919 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994770 → |
TCFY3621MTANM+ furnace: S802V0754A17UHCold climate designationAHRI reference: 216891920 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994771 → |
TCFY3621MTANM+ furnace: S97MV0603A17DHCold climate designationAHRI reference: 216891921 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994772 → |
TCFY3621MTANM+ furnace: S801V1005A21DZCold climate designationAHRI reference: 216891922 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3994773 → |
TCFY3617STANM+ furnace: S801V0754A17UHCold climate designationAHRI reference: 216891946 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994805 → |
TCFY3621STANM+ furnace: S801V1005A21DZCold climate designationAHRI reference: 216891947 | 19.00 | 8.50 | 27400 | 2.00 | EPA 3994806 → |
TCFY3617STANM+ furnace: S801V0754A17DZCold climate designationAHRI reference: 216891948 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994807 → |
TCFY3621STANM+ furnace: S921V0855A21M4Cold climate designationAHRI reference: 216891949 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994808 → |
TCFY3621STANM+ furnace: S98MV1005A21UPCold climate designationAHRI reference: 216891953 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994813 → |
TCFY3621STANM+ furnace: S801V0754A17UHCold climate designationAHRI reference: 216891954 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994814 → |
TCFY3621STANM+ furnace: S98MV0703A17UPCold climate designationAHRI reference: 216891963 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994823 → |
TCFY3617STANM+ furnace: S802V1004A17UHCold climate designationAHRI reference: 216891965 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994824 → |
TCFY3621STANM+ furnace: S802V0755A21DZCold climate designationAHRI reference: 216891966 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994825 → |
TCFY3617STANM+ furnace: S801V1004A17UHCold climate designationAHRI reference: 216891970 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994827 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →