RD18AY36AJVC
VANTIX · source records, page 4
192 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 192 / 192 |
| EER2 · BTU/Wh | 11.7–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 8.1–10 | 192 / 192 |
| Cooling capacity · BTU/h | 31,000–32,800 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–28,200 | 192 / 192 |
| COP at 5°F / −15°C | 1.9–2.2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | Yes | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY3621STANM+ furnace: S802V1004A17UHCold climate designationAHRI reference: 216892011 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994885 → |
TCFY3621STANM+ furnace: S802V1005A21UHCold climate designationAHRI reference: 216892016 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994889 → |
TCFY3621STANM+ furnace: S97MV0603A17DHCold climate designationAHRI reference: 216892017 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994890 → |
TCFY3621STANM+ furnace: S801V0755A21DZCold climate designationAHRI reference: 216892018 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994892 → |
TCFY3621STANM+ furnace: S801V1005A21UHNCold climate designationAHRI reference: 216892021 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994893 → |
TCFY3624MTANM+ furnace: S951V1005A21UHCold climate designationAHRI reference: 216892035 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994932 → |
TCFY3624MTANM+ furnace: S801V0755A21UHCold climate designationAHRI reference: 216892037 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994937 → |
TCFY3624MTANM+ furnace: S801V1505A24UHCold climate designationAHRI reference: 216892038 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994944 → |
TCFY3624MTANM+ furnace: S98MV1005A21UPCold climate designationAHRI reference: 216892045 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994946 → |
TCFY3624MTANM+ furnace: S921V1155A24M4Cold climate designationAHRI reference: 216892030 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3994952 → |
TCFY3624MTANM+ furnace: S802V1005A21UHCold climate designationAHRI reference: 216892031 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994953 → |
TCFY3624MTANM+ furnace: S802V1255A24DZCold climate designationAHRI reference: 216892034 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994954 → |
TCFY3624MTANM+ furnace: S801V1005A21UHSCold climate designationAHRI reference: 216892032 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994956 → |
TCFY3624MTANM+ furnace: S962V0855A21M4Cold climate designationAHRI reference: 216892033 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994957 → |
TCFY3624MTANM+ furnace: S801V0755A21DZCold climate designationAHRI reference: 216892043 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994960 → |
TCFY3624MTANM+ furnace: S801V1005A21UHNCold climate designationAHRI reference: 216892039 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994962 → |
TCFY3624MTANM+ furnace: S951V0855A21M4Cold climate designationAHRI reference: 216892041 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994963 → |
TCFY3624MTANM+ furnace: S97MV1005A21DHCold climate designationAHRI reference: 216892042 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994964 → |
TCFY3624MTANM+ furnace: S921V0855A21M4Cold climate designationAHRI reference: 216892046 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994965 → |
TCFY3624MTANM+ furnace: S802V1505A24UHCold climate designationAHRI reference: 216892047 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994967 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →