SINCLAIR AIR CONDITIONING / AIR-SOURCE HEAT PUMP

BH714S24P-**A

BH714S SERIES · BH714S Series · source records, page 3

82 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for BH714S24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 82 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1682 / 82
EER2 · BTU/Wh12–13.882 / 82
HSPF2 · BTU/Wh7.8–8.282 / 82
Cooling capacity · BTU/h22,800–24,00082 / 82
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00082 / 82
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70082 / 82
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60082 / 82
COP at 5°F / −15°C1.96–2.1882 / 82
Equipment / loop typeHP - Split System82 / 82
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)82 / 82
Compressor stagingSingle stage82 / 82
Connected capabilityNo82 / 82

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC730HBT-**+TDR+ furnace: B92UR451E3BAHRI reference: 21637210915.208.00112002.06EPA 3813418
BC730/36DBT-**+TDR+ furnace: B80DR901E4BAHRI reference: 21637212515.208.20113002.10EPA 3813429
BC730HBT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21637211315.207.80110002.04EPA 3813439
BC730HBT-**+TDR+ furnace: B97UR402V3BXAHRI reference: 21637211415.207.80110002.04EPA 3813440
BC724[C,U]BT-**+TDR+ furnace: B92UR451E3BAHRI reference: 21637204315.207.80110002.02EPA 3813445
BC724[C,U]BT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21637204415.207.80110002.04EPA 3813446
BC730[C,U]BT-**+TDR+ furnace: B97UR402V3BXAHRI reference: 21637207015.207.80115002.12EPA 3813447
BC730[C,U]BT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21637207115.208.00113002.12EPA 3813448
BC724HAT-**+TDR+ furnace: B80UR701E3AAHRI reference: 21637207615.207.80107001.98EPA 3813449
BC724HAT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 21637207715.207.80107001.96EPA 3813450
BC724HBT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21637208815.208.10108002.00EPA 3813462
BC724HBT-**+TDR+ furnace: B96UR701E4BAHRI reference: 21637209015.208.10108002.00EPA 3813463
BC724[C,U]AT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21637202815.207.80110002.02EPA 3813469
BC724[C,U]AT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21637202915.207.80110002.02EPA 3813470
BC730HAT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21637209415.208.00112002.02EPA 3813471
BC730HAT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21637209515.208.00112002.02EPA 3813472
BC730HAT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21637209615.208.00113002.04EPA 3813473
BC730HAT-**+TDR+ furnace: B80UR451E3AAHRI reference: 21637209715.207.80109002.02EPA 3813474
BC730HAT-**+TDR+ furnace: B80UR701E3AAHRI reference: 21637209815.208.00110002.04EPA 3813475
BC730HAT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 21637209915.208.00111002.04EPA 3813476

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →