SINCLAIR AIR CONDITIONING / AIR-SOURCE HEAT PUMP

BH714S24P-**A

BH714S SERIES · BH714S Series · source records, page 2

82 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for BH714S24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 82 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1682 / 82
EER2 · BTU/Wh12–13.882 / 82
HSPF2 · BTU/Wh7.8–8.282 / 82
Cooling capacity · BTU/h22,800–24,00082 / 82
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00082 / 82
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70082 / 82
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60082 / 82
COP at 5°F / −15°C1.96–2.1882 / 82
Equipment / loop typeHP - Split System82 / 82
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)82 / 82
Compressor stagingSingle stage82 / 82
Connected capabilityNo82 / 82

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC724[C,U]BT-**+TDR+ furnace: B80UR701E3BAHRI reference: 21637204115.507.80108002.04EPA 3813489
BC724[C,U]BT-**+TDR+ furnace: B80UR901E4BAHRI reference: 21637204215.508.00108002.04EPA 3813490
BC730HBT-**+TDR+ furnace: B80UR901E4BAHRI reference: 21637210815.508.10110002.10EPA 3813805
BC730[C,U]BT-**+TDR+ furnace: B80UR902E3BAHRI reference: 21637205915.507.80111002.12EPA 3813825
BC730[C,U]AT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21680163915.508.00114002.14EPA 3993063
BC730[C,U]BT-**+TDR+ furnace: B97UR702V3BAHRI reference: 21680164115.508.00113002.16EPA 3993064
BC724HBT-**+TDR+ furnace: B97UR702V3BAHRI reference: 21680164515.508.10106002.00EPA 3993103
BC730/36DCT-**+TDR+ furnace: B96DR901E4CAHRI reference: 21637212815.208.20113002.12EPA 3813378
BC724[C,U]AT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21637203015.207.80110002.02EPA 3813385
BC724[C,U]BT-**+TDR+ furnace: B80UR902E3BAHRI reference: 21637203715.207.80110002.02EPA 3813389
BC730[C,U]BT-**+TDR+ furnace: B92UR451E3BAHRI reference: 21637206515.208.00116002.14EPA 3813399
BC730[C,U]BT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21637206615.208.10115002.14EPA 3813401
BC724[C,U]BT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21637204715.207.80109002.00EPA 3813406
BC724[C,U]BT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21637204915.207.80108002.02EPA 3813407
BC730[C,U]AT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21637205015.208.00115002.14EPA 3813408
BC730[C,U]BT-**+TDR+ furnace: B96UR701E4BAHRI reference: 21637206815.208.10115002.14EPA 3813409
BC730[C,U]AT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21637205215.208.00116002.14EPA 3813410
BC730[C,U]BT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21637206915.207.80114002.12EPA 3813412
BC730HBT-**+TDR+ furnace: B95UR601E3BXAHRI reference: 21637210215.208.00112002.04EPA 3813413
BC730HBT-**+TDR+ furnace: B97UR452E3BAHRI reference: 21637210515.207.80112002.04EPA 3813416