SINCLAIR AIR CONDITIONING / AIR-SOURCE HEAT PUMP

BH714S24P-**A

BH714S SERIES · BH714S Series · source records, page 4

82 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for BH714S24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 82 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1682 / 82
EER2 · BTU/Wh12–13.882 / 82
HSPF2 · BTU/Wh7.8–8.282 / 82
Cooling capacity · BTU/h22,800–24,00082 / 82
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,00082 / 82
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,70082 / 82
Heating capacity at 5°F / −15°C · BTU/h10,500–11,60082 / 82
COP at 5°F / −15°C1.96–2.1882 / 82
Equipment / loop typeHP - Split System82 / 82
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)82 / 82
Compressor stagingSingle stage82 / 82
Connected capabilityNo82 / 82

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC730HBT-**+TDR+ furnace: B80UR801E4BXAHRI reference: 21637210015.208.00111002.06EPA 3813477
BC730HBT-**+TDR+ furnace: B95UR401E3BXAHRI reference: 21637210115.207.80112002.04EPA 3813478
BC730/36DCT-**+TDR+ furnace: B97DR902E4CAHRI reference: 21637212615.208.20113002.10EPA 3813788
BC730/36DCT-**+TDR+ furnace: B92DR901E4CAHRI reference: 21637212715.208.20114002.12EPA 3813789
BC724[C,U]BT-**+TDR+ furnace: B96UR701E4BAHRI reference: 21637204615.207.80110002.04EPA 3813802
BC730[C,U]AT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21637205115.208.00115002.14EPA 3813803
BC730HBT-**+TDR+ furnace: B97UR702E3BAHRI reference: 21637210615.207.80112002.04EPA 3813804
BC724HBT-**+TDR+ furnace: B80UR801E4BXAHRI reference: 21637207815.208.00108001.98EPA 3813814
BC724HBT-**+TDR+ furnace: B80UR902E3BAHRI reference: 21637208115.207.80105001.98EPA 3813815
BC730/36DBT-**+TDR+ furnace: B80DR902E4BAHRI reference: 21637212415.208.20114002.10EPA 3813817
BC730[C,U]BT-**+TDR+ furnace: B80UR801E4BXAHRI reference: 21637205615.208.00115002.12EPA 3813824
BAH7E24PT-**AHRI reference: 21637202315.207.80110002.06EPA 3813826
BC724[C,U]AT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21680163615.207.80109002.02EPA 3993061
BC724[C,U]BT-**+TDR+ furnace: B80UR902V4BAHRI reference: 21680163715.207.80108002.00EPA 3993062
BC730[C,U]BT-**+TDR+ furnace: B80UR902V4BAHRI reference: 21680164015.207.80114002.14EPA 3993066
BC724HAT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21680164315.207.80107001.96EPA 3993101
BC724HBT-**+TDR+ furnace: B80UR902V4BAHRI reference: 21680164415.208.00107001.98EPA 3993102
BC730HAT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21680164615.208.00111002.04EPA 3993104
BC730HBT-**+TDR+ furnace: B97UR702V3BAHRI reference: 21680164715.208.00109002.08EPA 3993105
BC730HBT-**+TDR+ furnace: B80UR902V4BAHRI reference: 21680164815.207.80109002.04EPA 3993106

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →