RP17AY36AJVC
Achiever Plus · source records, page 4
123 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RP17AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 123 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 123 / 123 |
| EER2 · BTU/Wh | 10–11 | 123 / 123 |
| HSPF2 · BTU/Wh | 9.5 | 123 / 123 |
| Cooling capacity · BTU/h | 34,000–34,200 | 123 / 123 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–34,200 | 123 / 123 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,000–32,600 | 123 / 123 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,400–31,400 | 123 / 123 |
| COP at 5°F / −15°C | 2 | 123 / 123 |
| Equipment / loop type | HP - Split System | 123 / 123 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 123 / 123 |
| Compressor staging | Continuously variable | 123 / 123 |
| Connected capability | Yes | 123 / 123 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3621STANM+ furnace: R97MV0703A17DHSCold climate designationAHRI reference: 218327690 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620069 → |
RCFY3617STANM+ furnace: R97MV0703A17DHSCold climate designationAHRI reference: 218327689 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620070 → |
RCFY3621STANM+ furnace: R97MV0603A17DHSCold climate designationAHRI reference: 218327688 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620071 → |
RCFY3617STANM+ furnace: R97MV0603A17DHSCold climate designationAHRI reference: 218327687 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620072 → |
RCFY3621STANM+ furnace: R962V1005A21M4SCold climate designationAHRI reference: 218327686 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4620073 → |
RCFY3621STANM+ furnace: R962V0705A21M4SCold climate designationAHRI reference: 218327684 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4620075 → |
RCFY3621STANM+ furnace: R962V0703A17M4SCold climate designationAHRI reference: 218327683 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620076 → |
RCFY3617STANM+ furnace: R962V0703A17M4SCold climate designationAHRI reference: 218327682 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620077 → |
RCFY3621STANM+ furnace: R962V0603A17M4SCold climate designationAHRI reference: 218327681 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620078 → |
RCFY3617STANM+ furnace: R962V0603A17M4SCold climate designationAHRI reference: 218327680 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620079 → |
RCFY3621STANM+ furnace: R962V0403A17M4SCold climate designationAHRI reference: 218327679 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620080 → |
RCFY3617STANM+ furnace: R962V0403A17M4SCold climate designationAHRI reference: 218327678 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620081 → |
RCFY3621STANM+ furnace: R951V0705A21M4SCold climate designationAHRI reference: 218327722 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4620849 → |
RCFY3621STANM+ furnace: R951V0703A17M4SCold climate designationAHRI reference: 218327721 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620850 → |
RCFY3617STANM+ furnace: R951V0703A17M4SCold climate designationAHRI reference: 218327720 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620851 → |
RCFY3621STANM+ furnace: R951V0603A17UHUCold climate designationAHRI reference: 218327719 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4620852 → |
RCFY3617STANM+ furnace: R951V0603A17UHUCold climate designationAHRI reference: 218327718 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4620853 → |
RCFY3621STANM+ furnace: R951V0603A17M4UCold climate designationAHRI reference: 218327717 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4620854 → |
RCFY3617STANM+ furnace: R951V0603A17M4UCold climate designationAHRI reference: 218327716 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4620855 → |
RCFY3621STANM+ furnace: R951V0603A17M4SCold climate designationAHRI reference: 218327715 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620856 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →