RP17AY36AJVC
Achiever Plus · source records, page 5
123 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RP17AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 123 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 123 / 123 |
| EER2 · BTU/Wh | 10–11 | 123 / 123 |
| HSPF2 · BTU/Wh | 9.5 | 123 / 123 |
| Cooling capacity · BTU/h | 34,000–34,200 | 123 / 123 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–34,200 | 123 / 123 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,000–32,600 | 123 / 123 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,400–31,400 | 123 / 123 |
| COP at 5°F / −15°C | 2 | 123 / 123 |
| Equipment / loop type | HP - Split System | 123 / 123 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 123 / 123 |
| Compressor staging | Continuously variable | 123 / 123 |
| Connected capability | Yes | 123 / 123 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3617STANM+ furnace: R951V0603A17M4SCold climate designationAHRI reference: 218327714 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620857 → |
RCFY3621STANM+ furnace: R951V0403A17UHUCold climate designationAHRI reference: 218327713 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4620858 → |
RCFY3617STANM+ furnace: R951V0403A17UHUCold climate designationAHRI reference: 218327712 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4620859 → |
RCFY3621STANM+ furnace: R951V0403A17M4UCold climate designationAHRI reference: 218327711 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4620860 → |
RCFY3617STANM+ furnace: R951V0403A17M4UCold climate designationAHRI reference: 218327710 | 16.00 | 9.50 | 31400 | 2.00 | EPA 4620861 → |
RCFY3621STANM+ furnace: R951V0403A17M4SCold climate designationAHRI reference: 218327709 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620862 → |
RCFY3617STANM+ furnace: R951V0403A17M4SCold climate designationAHRI reference: 218327708 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620863 → |
RCFY3621STANM+ furnace: R921V1005A21M4SCold climate designationAHRI reference: 218327707 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4620864 → |
RCFY3621STANM+ furnace: R921V0705A21M4SCold climate designationAHRI reference: 218327705 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4620866 → |
RCFY3621STANM+ furnace: R921V0703A17M4SCold climate designationAHRI reference: 218327704 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620867 → |
RCFY3617STANM+ furnace: R921V0703A17M4SCold climate designationAHRI reference: 218327703 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620868 → |
RCFY3621STANM+ furnace: R921V0603A17M4SCold climate designationAHRI reference: 218327702 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620869 → |
RCFY3617STANM+ furnace: R921V0603A17M4SCold climate designationAHRI reference: 218327701 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620870 → |
RCFY3621STANM+ furnace: R921V0403A17M4SCold climate designationAHRI reference: 218327700 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620871 → |
RCFY3617STANM+ furnace: R921V0403A17M4SCold climate designationAHRI reference: 218327699 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620872 → |
RCFY3621STANM+ furnace: R98MV0703A17UPSCold climate designationAHRI reference: 218327696 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620875 → |
RCFY3617STANM+ furnace: R962V0403A14M4SCold climate designationAHRI reference: 218327677 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620876 → |
RCFY3621STANM+ furnace: R802V0504A17UHSCold climate designationAHRI reference: 218327656 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620897 → |
RCFY3617STANM+ furnace: R802V0504A17UHSCold climate designationAHRI reference: 218327655 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620898 → |
RCFY3621STANM+ furnace: R802V0504A17UHNCold climate designationAHRI reference: 218327654 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620899 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →