RP17AY36AJVC
Achiever Plus · source records, page 3
123 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RP17AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 123 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 123 / 123 |
| EER2 · BTU/Wh | 10–11 | 123 / 123 |
| HSPF2 · BTU/Wh | 9.5 | 123 / 123 |
| Cooling capacity · BTU/h | 34,000–34,200 | 123 / 123 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–34,200 | 123 / 123 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,000–32,600 | 123 / 123 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,400–31,400 | 123 / 123 |
| COP at 5°F / −15°C | 2 | 123 / 123 |
| Equipment / loop type | HP - Split System | 123 / 123 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 123 / 123 |
| Compressor staging | Continuously variable | 123 / 123 |
| Connected capability | Yes | 123 / 123 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3621STANM+ furnace: R801V0755A21UHSCold climate designationAHRI reference: 218327640 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620913 → |
RCFY3621STANM+ furnace: R801V0755A21UHNCold climate designationAHRI reference: 218327639 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620914 → |
RCFY3621STANM+ furnace: R801V0755A21DZSCold climate designationAHRI reference: 218327638 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620915 → |
RCFY3621STANM+ furnace: R801V0755A21DZNCold climate designationAHRI reference: 218327637 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620916 → |
RCFY3621STANM+ furnace: R801V0754A17UHSCold climate designationAHRI reference: 218327636 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620917 → |
RCFY3617STANM+ furnace: R801V0754A17UHSCold climate designationAHRI reference: 218327635 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620918 → |
RCFY3621STANM+ furnace: R801V0754A17UHNCold climate designationAHRI reference: 218327634 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620919 → |
RCFY3617STANM+ furnace: R801V0754A17UHNCold climate designationAHRI reference: 218327633 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620920 → |
RCFY3621STANM+ furnace: R801V0754A17DZSCold climate designationAHRI reference: 218327632 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620921 → |
RCFY3617STANM+ furnace: R801V0754A17DZSCold climate designationAHRI reference: 218327631 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620922 → |
RCFY3621STANM+ furnace: R801V0754A17DZNCold climate designationAHRI reference: 218327630 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620923 → |
RCFY3617STANM+ furnace: R801V0754A17DZNCold climate designationAHRI reference: 218327629 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620924 → |
RCFY3621STANM+ furnace: R972V0855A21UPSCold climate designationAHRI reference: 218719308 | 17.00 | 9.50 | 25400 | 2.00 | EPA 4691775 → |
RCFY3621STANM+ furnace: R972V0705A21UPSCold climate designationAHRI reference: 218719306 | 17.00 | 9.50 | 25400 | 2.00 | EPA 4691777 → |
RH2VY3617STACNCold climate designationAHRI reference: 218159985 | 16.50 | 9.50 | 31000 | 2.00 | EPA 4620254 → |
RCFY3617STANM+ furnace: R801V0504A17UHSCold climate designationAHRI reference: 218327877 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620060 → |
RCFY3621STANM+ furnace: R951V1005A21M4SCold climate designationAHRI reference: 218327726 | 16.00 | 9.50 | 31000 | 2.00 | EPA 4620063 → |
RCFY3617STANM+ furnace: R98MV0703A17UPSCold climate designationAHRI reference: 218327695 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620064 → |
RCFY3621STANM+ furnace: R98MV0603A17UPSCold climate designationAHRI reference: 218327694 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620065 → |
RCFY3617STANM+ furnace: R98MV0603A17UPSCold climate designationAHRI reference: 218327693 | 16.00 | 9.50 | 31200 | 2.00 | EPA 4620066 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →