RP17AY36AJVC
Achiever Plus · source records, page 2
123 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RP17AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 123 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–17 | 123 / 123 |
| EER2 · BTU/Wh | 10–11 | 123 / 123 |
| HSPF2 · BTU/Wh | 9.5 | 123 / 123 |
| Cooling capacity · BTU/h | 34,000–34,200 | 123 / 123 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–34,200 | 123 / 123 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,000–32,600 | 123 / 123 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,400–31,400 | 123 / 123 |
| COP at 5°F / −15°C | 2 | 123 / 123 |
| Equipment / loop type | HP - Split System | 123 / 123 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 123 / 123 |
| Compressor staging | Continuously variable | 123 / 123 |
| Connected capability | Yes | 123 / 123 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3621STANM+ furnace: R802V0755A21UHNCold climate designationAHRI reference: 218327667 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620886 → |
RCFY3621STANM+ furnace: R802V0755A21DZSCold climate designationAHRI reference: 218327666 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620887 → |
RCFY3621STANM+ furnace: R802V0755A21DZNCold climate designationAHRI reference: 218327665 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620888 → |
RCFY3621STANM+ furnace: R802V0754A17UHSCold climate designationAHRI reference: 218327664 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620889 → |
RCFY3617STANM+ furnace: R802V0754A17UHSCold climate designationAHRI reference: 218327663 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620890 → |
RCFY3621STANM+ furnace: R802V0754A17UHNCold climate designationAHRI reference: 218327662 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620891 → |
RCFY3617STANM+ furnace: R802V0754A17UHNCold climate designationAHRI reference: 218327661 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620892 → |
RCFY3621STANM+ furnace: R802V0754A17DZSCold climate designationAHRI reference: 218327660 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620893 → |
RCFY3617STANM+ furnace: R802V0754A17DZSCold climate designationAHRI reference: 218327659 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620894 → |
RCFY3621STANM+ furnace: R802V0754A17DZNCold climate designationAHRI reference: 218327658 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620895 → |
RCFY3617STANM+ furnace: R802V0754A17DZNCold climate designationAHRI reference: 218327657 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620896 → |
RCFY3621STANM+ furnace: R801V1005A21UHUCold climate designationAHRI reference: 218327649 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620904 → |
RCFY3621STANM+ furnace: R801V1005A21UHSCold climate designationAHRI reference: 218327648 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620905 → |
RCFY3621STANM+ furnace: R801V1005A21UHNCold climate designationAHRI reference: 218327647 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620906 → |
RCFY3621STANM+ furnace: R801V1005A21DZSCold climate designationAHRI reference: 218327646 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620907 → |
RCFY3621STANM+ furnace: R801V1005A21DZNCold climate designationAHRI reference: 218327645 | 17.00 | 9.50 | 30800 | 2.00 | EPA 4620908 → |
RCFY3621STANM+ furnace: R801V1004A17UHSCold climate designationAHRI reference: 218327644 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620909 → |
RCFY3617STANM+ furnace: R801V1004A17UHSCold climate designationAHRI reference: 218327643 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620910 → |
RCFY3621STANM+ furnace: R801V1004A17UHNCold climate designationAHRI reference: 218327642 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620911 → |
RCFY3617STANM+ furnace: R801V1004A17UHNCold climate designationAHRI reference: 218327641 | 17.00 | 9.50 | 31000 | 2.00 | EPA 4620912 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →