RUSSELL / AIR-SOURCE HEAT PUMP

RD18AY36AJVC

VANTIX · source records, page 5

192 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range8.1–10BTU/Wh
Cooling capacity31,000–32,800BTU/h

Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20192 / 192
EER2 · BTU/Wh11.7–13192 / 192
HSPF2 · BTU/Wh8.1–10192 / 192
Cooling capacity · BTU/h31,000–32,800192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h31,000–36,000192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h28,000–31,000192 / 192
Heating capacity at 5°F / −15°C · BTU/h23,600–28,200192 / 192
COP at 5°F / −15°C1.9–2.2192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)192 / 192
Compressor stagingContinuously variable192 / 192
Connected capabilityYes192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
TCFY3624MTANM+ furnace: S97MV1155A24DHCold climate designationAHRI reference: 21689226419.0010.00278002.10EPA 3995289 →
TCFY3624MTANM+ furnace: S802V1255A24UHCold climate designationAHRI reference: 21689226619.0010.00278002.10EPA 3995291 →
TCFY3621MTANM+ furnace: S801V0754A17UHCold climate designationAHRI reference: 21689212119.0010.00278002.10EPA 3995314 →
TCFY3621MTANM+ furnace: S802V1004A17UHCold climate designationAHRI reference: 21689212219.0010.00278002.10EPA 3995315 →
TCFY3621MTANM+ furnace: S802V0754A17UHCold climate designationAHRI reference: 21689212319.0010.00278002.10EPA 3995316 →
TCFY3621MTANM+ furnace: S97MV0603A17DHCold climate designationAHRI reference: 21689212419.0010.00280002.10EPA 3995317 →
TCFY3621STANM+ furnace: S802V0755A21DZCold climate designationAHRI reference: 21689216919.008.50276002.00EPA 3995321 →
TCFY3617STANM+ furnace: S801V0754A17UHCold climate designationAHRI reference: 21689214919.008.50276002.00EPA 3995322 →
TCFY3621STANM+ furnace: S801V1005A21DZCold climate designationAHRI reference: 21689215019.008.50274002.00EPA 3995323 →
TCFY3621STANM+ furnace: S921V0855A21M4Cold climate designationAHRI reference: 21689215219.008.50278001.90EPA 3995324 →
TCFY3617STANM+ furnace: S801V0754A17DZCold climate designationAHRI reference: 21689215119.008.50276001.90EPA 3995325 →
TCFY3621STANM+ furnace: S98MV1005A21UPCold climate designationAHRI reference: 21689215619.008.50278001.90EPA 3995328 →
TCFY3621STANM+ furnace: S801V0754A17UHCold climate designationAHRI reference: 21689215719.008.50276001.90EPA 3995329 →
TCFY3621STANM+ furnace: S98MV0703A17UPCold climate designationAHRI reference: 21689216619.008.50278001.90EPA 3995340 →
TCFY3617STANM+ furnace: S802V1004A17UHCold climate designationAHRI reference: 21689216819.008.50276001.90EPA 3995341 →
TCFY3621STANM+ furnace: S951V0855A21M4Cold climate designationAHRI reference: 21689217119.008.50278001.90EPA 3995343 →
SH2CY3621STANNCold climate designationAHRI reference: 21716599019.008.50274002.00EPA 4010296 →
SH2CY3617STANNCold climate designationAHRI reference: 21716599119.008.50276001.90EPA 4010297 →
SH2VY3621MTACNCold climate designationAHRI reference: 21716601519.0010.00278002.10EPA 4010312 →
TCFY3621STANM+ furnace: S972V1005A21UPSAHRI reference: 21872957519.008.50252002.10EPA 4704699 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.