Heating performance & equipment details
Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 192 / 192 |
| EER2 · BTU/Wh | 11.7–13 | 192 / 192 |
| HSPF2 · BTU/Wh | 8.1–10 | 192 / 192 |
| Cooling capacity · BTU/h | 31,000–32,800 | 192 / 192 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 192 / 192 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 192 / 192 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–28,200 | 192 / 192 |
| COP at 5°F / −15°C | 1.9–2.2 | 192 / 192 |
| Equipment / loop type | HP - Split System | 192 / 192 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 192 / 192 |
| Compressor staging | Continuously variable | 192 / 192 |
| Connected capability | Yes | 192 / 192 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY3624MTANM+ furnace: S801V0755A21UHCold climate designationAHRI reference: 216892240 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995266 → |
TCFY3624MTANM+ furnace: S801V1005A21UHNCold climate designationAHRI reference: 216892242 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995267 → |
TCFY3624MTANM+ furnace: S951V0855A21M4Cold climate designationAHRI reference: 216892244 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3995269 → |
TCFY3624MTANM+ furnace: S801V0755A21DZCold climate designationAHRI reference: 216892246 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995270 → |
TCFY3624MTANM+ furnace: S97MV1005A21DHCold climate designationAHRI reference: 216892245 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995272 → |
TCFY3624MTANM+ furnace: S98MV1005A21UPCold climate designationAHRI reference: 216892248 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3995273 → |
TCFY3624MTANM+ furnace: S921V0855A21M4Cold climate designationAHRI reference: 216892249 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3995274 → |
TCFY3624MTANM+ furnace: S802V1505A24UHCold climate designationAHRI reference: 216892250 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995275 → |
TCFY3624MTANM+ furnace: S801V1255A24DZCold climate designationAHRI reference: 216892252 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995277 → |
TCFY3624MTANM+ furnace: S951V0705A21UHUCold climate designationAHRI reference: 216892253 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995278 → |
TCFY3624MTANM+ furnace: S802V0755A21UHCold climate designationAHRI reference: 216892255 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995279 → |
TCFY3624MTANM+ furnace: S97MV0855A21DHCold climate designationAHRI reference: 216892254 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995280 → |
TCFY3624MTANM+ furnace: S98MV1155A24UPCold climate designationAHRI reference: 216892256 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995281 → |
TCFY3624MTANM+ furnace: S801V1005A21DZCold climate designationAHRI reference: 216892257 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3995282 → |
TCFY3624MTANM+ furnace: S802V1005A21DZCold climate designationAHRI reference: 216892258 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3995283 → |
TCFY3624MTANM+ furnace: S951V1155A24M4Cold climate designationAHRI reference: 216892261 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3995284 → |
TCFY3624MTANM+ furnace: S801V1005A21UHUCold climate designationAHRI reference: 216892260 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995285 → |
TCFY3624MTANM+ furnace: S98MV0855A21UPCold climate designationAHRI reference: 216892259 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995286 → |
TCFY3624MTANM+ furnace: S801V1255A24UHCold climate designationAHRI reference: 216892262 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995287 → |
TCFY3624MTANM+ furnace: S802V0755A21DZCold climate designationAHRI reference: 216892263 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995288 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →