RUSSELL / AIR-SOURCE HEAT PUMP

RD18AY36AJVC

VANTIX · source records, page 6

192 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range8.1–10BTU/Wh
Cooling capacity31,000–32,800BTU/h

Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20192 / 192
EER2 · BTU/Wh11.7–13192 / 192
HSPF2 · BTU/Wh8.1–10192 / 192
Cooling capacity · BTU/h31,000–32,800192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h31,000–36,000192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h28,000–31,000192 / 192
Heating capacity at 5°F / −15°C · BTU/h23,600–28,200192 / 192
COP at 5°F / −15°C1.9–2.2192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)192 / 192
Compressor stagingContinuously variable192 / 192
Connected capabilityYes192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
TCFY3621STANM+ furnace: S972V0855A21UPSAHRI reference: 21872957319.008.50252002.10EPA 4704701
TCFY3621STANM+ furnace: S972V0705A21UPSAHRI reference: 21872957119.008.50252002.10EPA 4704703
TCFY3621STANM+ furnace: S972V0703A17UPSAHRI reference: 21872956919.008.50254002.10EPA 4704705
TCFY3617STANM+ furnace: S972V0703A17UPSAHRI reference: 21872956719.008.50252002.10EPA 4704707
TCFY3621MTANM+ furnace: S972V0855A21UPSAHRI reference: 21872951919.0010.00236002.20EPA 4704755
TCFY3624MTANM+ furnace: S972V0705A21UPSAHRI reference: 21872951719.0010.00236002.20EPA 4704757
TCFY3621MTANM+ furnace: S972V0705A21UPSAHRI reference: 21872951519.0010.00236002.20EPA 4704759
TCFY3617STANM+ furnace: S801V0504A17UHNCold climate designationAHRI reference: 21689226818.008.50278001.90EPA 3994458
TCFY3621STANM+ furnace: S951V0703A17M4Cold climate designationAHRI reference: 21689226918.008.50278001.90EPA 3994459
TCFY3621MTANM+ furnace: S801V0504A17UHSCold climate designationAHRI reference: 21689207618.0010.00280002.10EPA 3994975
TCFY3621MTANM+ furnace: S962V0705A21M4Cold climate designationAHRI reference: 21689208118.0010.00280002.10EPA 3994982
TCFY3621MTANM+ furnace: S801V0704A17UHCold climate designationAHRI reference: 21689208818.0010.00280002.10EPA 3995032
TCFY3621MTANM+ furnace: S801V0504A17UHNCold climate designationAHRI reference: 21689207818.0010.00280002.10EPA 3995042
TCFY3621MTANM+ furnace: S921V0703A17M4Cold climate designationAHRI reference: 21689208018.0010.00280002.10EPA 3995045
TCFY3621MTANM+ furnace: S921V1005A21M4Cold climate designationAHRI reference: 21689208418.0010.00280002.10EPA 3995048
TCFY3621MTANM+ furnace: S951V0603A17UHCold climate designationAHRI reference: 21689208718.0010.00282002.10EPA 3995052
TCFY3621MTANM+ furnace: S921V0403A17M4Cold climate designationAHRI reference: 21689209118.0010.00280002.10EPA 3995056
TCFY3621MTANM+ furnace: S921V0603A17M4Cold climate designationAHRI reference: 21689209418.0010.00280002.10EPA 3995057
TCFY3621MTANM+ furnace: S951V1005A21M4Cold climate designationAHRI reference: 21689209718.0010.00280002.10EPA 3995060
TCFY3621MTANM+ furnace: S951V0403A17M4Cold climate designationAHRI reference: 21689209618.0010.00280002.10EPA 3995061

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →