ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17 Series · 4HP17L SERIES · source records, page 4

89 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 89 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.689 / 89
EER2 · BTU/Wh12.5–1389 / 89
HSPF2 · BTU/Wh8–8.589 / 89
Cooling capacity · BTU/h46,000–48,00089 / 89
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,00089 / 89
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,60089 / 89
Heating capacity at 5°F / −15°C · BTU/h24,200–25,60089 / 89
COP at 5°F / −15°C2.16–2.3889 / 89
Equipment / loop typeHP - Split System89 / 89
Refrigerant / source-reported GWPR-410A (GWP:2088)89 / 89
Compressor stagingSingle stage89 / 89
Connected capabilityNo89 / 89

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X48C+TDR+ furnace: 80G2UH110CE16AHRI reference: 21032683415.208.10244002.20EPA 2459029
EA(C;U)1P60C+TDR+TXV+ furnace: 95G1UH100CE20XAHRI reference: 21032678815.208.10254002.38EPA 2459040
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032680215.208.10242002.18EPA 2459273
EAC4X60C+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21032685215.208.10254002.38EPA 2459275
EA(C;U)1P49C+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21032677515.208.10254002.26EPA 2459292
EAC4X49C+TDR+ furnace: 92G1UH110CE16AHRI reference: 21032684415.208.10254002.22EPA 2459524
BCE5V48M*4XAHRI reference: 21032675915.208.30242002.28EPA 2459716
EA(C;U)1P48B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21032676215.208.10242002.18EPA 2459749
EA(C;U)1P60C+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21032679415.208.10252002.34EPA 2459758
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21032680315.208.10242002.18EPA 2460372
EAC4X49C+TDR+ furnace: 96G1UH090CE16AHRI reference: 21032684515.208.10254002.24EPA 2461430
EAC4X48B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21032682615.208.10242002.18EPA 2462381
EAC4X48C+TDR+ furnace: 92G1UH110CE16AHRI reference: 21032683315.208.10244002.18EPA 2462387
EA(C;U)1P49C+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21032678015.208.10254002.22EPA 2462428
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173697015.208.10246002.16EPA 2462829
EAH1P60D*+TDR+TXV+ furnace: 96G1UH135DE20AHRI reference: 21173734115.208.10246002.20EPA 2462839
EAH1P48C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173707715.208.00244002.18EPA 2463294
EAH1P48C*+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21173715115.208.00248002.18EPA 2463704
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21173698315.208.00246002.18EPA 2467981
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21173699715.208.00246002.18EPA 2467985

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →