ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17 Series · 4HP17L SERIES · source records, page 3

89 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 89 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.689 / 89
EER2 · BTU/Wh12.5–1389 / 89
HSPF2 · BTU/Wh8–8.589 / 89
Cooling capacity · BTU/h46,000–48,00089 / 89
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,00089 / 89
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,60089 / 89
Heating capacity at 5°F / −15°C · BTU/h24,200–25,60089 / 89
COP at 5°F / −15°C2.16–2.3889 / 89
Equipment / loop typeHP - Split System89 / 89
Refrigerant / source-reported GWPR-410A (GWP:2088)89 / 89
Compressor stagingSingle stage89 / 89
Connected capabilityNo89 / 89

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21173720515.408.30254002.28EPA 2463278
EAH1P51C*+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21173729615.408.30254002.28EPA 2463694
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173719815.408.30256002.30EPA 2468417
EAH1P51C*+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21173727915.408.30256002.32EPA 2469329
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21173721215.408.30254002.28EPA 2469335
EAC4X50/60C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032686715.208.10242002.18EPA 2455576
EAC4X50/60C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032686615.208.10242002.18EPA 2455628
EA(C;U)1P49C+TDR+TXV+ furnace: 80G1UH110CE20AHRI reference: 21032677915.208.10256002.26EPA 2455938
EAC4X60C+TDR+ furnace: 92G1UH090CE16AHRI reference: 21032685815.208.10252002.34EPA 2455941
EAC4X49C+TDR+ furnace: 80G1UH110CE20AHRI reference: 21032684315.208.10256002.26EPA 2455953
EA(C;U)1P49C+TDR+TXV+ furnace: 96G1UH090CE16AHRI reference: 21032678115.208.10254002.24EPA 2455957
EAC4X49C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21032683915.208.10254002.26EPA 2455979
EA(C;U)1P48C+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21032676715.208.10242002.18EPA 2457665
EA(C;U)1P48C+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21032676915.208.10244002.18EPA 2457902
EA(C;U)1P49C+TDR+TXV+ furnace: 80G2UH110CV20AHRI reference: 21032678415.208.10256002.26EPA 2457903
EA(C;U)1P48C+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21032677015.208.10244002.20EPA 2458137
EAC4X50/60C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21032686515.208.00242002.18EPA 2458164
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21032680115.208.00242002.18EPA 2458447
EAC4X49C+TDR+ furnace: 80G2UH110CV20AHRI reference: 21032684815.208.10256002.26EPA 2458460
EAC4X48C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21032683115.208.10242002.18EPA 2458759