ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series

141 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.6BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 141 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.6141 / 141
EER2 · BTU/Wh12.2–13.5141 / 141
HSPF2 · BTU/Wh7.8–8.7141 / 141
Cooling capacity · BTU/h34,800–36,000141 / 141
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000141 / 141
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800141 / 141
Heating capacity at 5°F / −15°C · BTU/h16,800–19,100141 / 141
COP at 5°F / −15°C2.08–2.36141 / 141
Equipment / loop typeHP - Split System141 / 141
Refrigerant / source-reported GWPR-410A (GWP:2088)141 / 141
Compressor stagingSingle stage141 / 141
Connected capabilityNo141 / 141

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P36B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21044230716.607.80168002.14EPA 2456521
EAC4X36B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21032700316.607.80168002.14EPA 2458452
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21173658416.608.10175002.24EPA 2466184
EAH1P51C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173669216.608.00174002.22EPA 2467517
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173657116.608.00171002.20EPA 2468831
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21173659716.608.10175002.24EPA 2468850
EAD4X-48C+TDR+ furnace: 80G1DF110CE20AHRI reference: 21326539116.608.70188002.34EPA 2839879
EAC4X50/60C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21032702016.407.80170002.12EPA 2455493
EAC4X50/60C+TDR+ furnace: 80G2UH110CE16AHRI reference: 21032703416.407.80170002.12EPA 2455828
EAC4X36B+TDR+ furnace: 80G2UH090BE16AHRI reference: 21032700416.407.80170002.14EPA 2455982
EA(C;U)1P36B+TDR+TXV+ furnace: 80G2UH090BE16AHRI reference: 21032692216.407.80170002.14EPA 2458476
EAC4X50/60C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032702316.407.80171002.16EPA 2459032
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21032693916.407.80171002.16EPA 2459279
EAC4X36B+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21032700516.407.80170002.14EPA 2459322
EAC4X50/60C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032702216.407.80171002.16EPA 2459328
EA(C;U)1P36B+TDR+TXV+ furnace: 80G2UH090BE16LAHRI reference: 21032692316.407.80170002.14EPA 2459571
EA(C;U)1P36B+TDR+TXV+ furnace: 80G2UH090BE12AHRI reference: 21032692716.407.80170002.14EPA 2459736
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032693816.407.80171002.16EPA 2460064
EAC4X36B+TDR+ furnace: 80G2UH090BE12AHRI reference: 21032700916.407.80170002.14EPA 2461407
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21032695016.407.80170002.12EPA 2462161

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →