ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 4

135 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 135 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2135 / 135
EER2 · BTU/Wh12.2–13.5135 / 135
HSPF2 · BTU/Wh7.8–8.6135 / 135
Cooling capacity · BTU/h28,200–30,000135 / 135
Heating capacity at 47°F / 8.3°C · BTU/h27,200–30,000135 / 135
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600135 / 135
Heating capacity at 5°F / −15°C · BTU/h13,400–15,400135 / 135
COP at 5°F / −15°C1.96–2.36135 / 135
Equipment / loop typeHP - Split System135 / 135
Refrigerant / source-reported GWPR-410A (GWP:2088)135 / 135
Compressor stagingSingle stage135 / 135
Connected capabilityNo135 / 135

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P36C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173594615.808.30145002.22EPA 2467532
EAH1P30A*+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21173580915.807.80138002.00EPA 2468388
EAD4X-42B+TDR+ furnace: 92G1DF045BE12AHRI reference: 21326537115.808.60153002.34EPA 2839883
EAD4X-42B+TDR+ furnace: 92G1DF070BE12AHRI reference: 21326537215.808.60153002.32EPA 2839884
EAD4X-42B+TDR+ furnace: 80G2DF090BE16AHRI reference: 21326536615.808.60151002.32EPA 2839936
EAD4X-42B+TDR+ furnace: 80G1DF070BE12AHRI reference: 21326536915.808.60153002.34EPA 2839939
7EH30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21483164715.808.00137002.08EPA 3544450
EAC4X30B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21032716315.608.00144002.20EPA 2455858
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032706115.608.00144002.20EPA 2455970
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032706215.608.00144002.20EPA 2455975
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032706615.608.00145002.20EPA 2456004
EAC4X36B+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21032719015.608.10146002.24EPA 2456047
EAC4X30A+TDR+ furnace: 80G1UH070AE12AHRI reference: 21032715315.608.00144002.20EPA 2457015
EAC4X36B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032719415.608.10143002.26EPA 2457226
EA(C;U)1P30B+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21032708515.608.10145002.18EPA 2457227
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21032707215.608.00144002.20EPA 2457235
EA(C;U)1P36B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21032711015.608.00143002.24EPA 2457412
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 21032705915.608.00144002.20EPA 2457424
EAC4X30B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21032717315.608.00143002.20EPA 2457426
EA(C;U)1P36B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032710115.608.10146002.26EPA 2457427