ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 3

135 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 135 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2135 / 135
EER2 · BTU/Wh12.2–13.5135 / 135
HSPF2 · BTU/Wh7.8–8.6135 / 135
Cooling capacity · BTU/h28,200–30,000135 / 135
Heating capacity at 47°F / 8.3°C · BTU/h27,200–30,000135 / 135
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600135 / 135
Heating capacity at 5°F / −15°C · BTU/h13,400–15,400135 / 135
COP at 5°F / −15°C1.96–2.36135 / 135
Equipment / loop typeHP - Split System135 / 135
Refrigerant / source-reported GWPR-410A (GWP:2088)135 / 135
Compressor stagingSingle stage135 / 135
Connected capabilityNo135 / 135

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21032717215.808.00144002.22EPA 2456992
EAC4X36A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032718615.808.10144002.26EPA 2456998
EAC4X36A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21032718415.808.00144002.26EPA 2457232
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21032709115.808.00144002.26EPA 2457899
EAC4X36B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032719615.808.10142002.26EPA 2458141
EAC4X30A+TDR+ furnace: 80G2UH045AE12AHRI reference: 21032715715.808.10143002.24EPA 2458440
EAC4X36B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21032719115.808.10143002.26EPA 2458444
EA(C;U)1P30B+TDR+TXV+ furnace: 80G2UH090BE12AHRI reference: 21032707715.808.10143002.24EPA 2458471
EAC4X36B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21032720115.808.10142002.26EPA 2458728
EA(C;U)1P36B+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21032710915.808.10142002.26EPA 2458731
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032706515.808.10143002.24EPA 2458909
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21032709215.808.00144002.26EPA 2458911
EAC4X30B+TDR+ furnace: 80G2UH090BE12AHRI reference: 21032716915.808.10143002.24EPA 2459015
EAC4X30A+TDR+ furnace: 80G1UH045AE12AHRI reference: 21032715215.808.00141002.20EPA 2459024
BCE7E30M*4XAHRI reference: 21032705615.808.50147002.36EPA 2460616
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 21032708015.808.00144002.22EPA 2461162
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032709415.808.10144002.26EPA 2461167
EAH1P36C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173606315.808.50148002.26EPA 2462792
EAH1P36C*+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21173612515.808.30147002.24EPA 2462799
BCE7S36M*4XAHRI reference: 21185561515.808.10149002.36EPA 2464541

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →