SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 145 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8145 / 145
EER2 · BTU/Wh12.2–14145 / 145
HSPF2 · BTU/Wh7.8–8.5145 / 145
Cooling capacity · BTU/h18,000145 / 145
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,000145 / 145
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100145 / 145
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700145 / 145
COP at 5°F / −15°C1.9–2.16145 / 145
Equipment / loop typeHP - Split System145 / 145
Refrigerant / source-reported GWPR-410A (GWP:2088)145 / 145
Compressor stagingSingle stage145 / 145
Connected capabilityNo145 / 145

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21032741616.007.8078001.96EPA 2455657
EAC4X24B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21032750416.008.1084002.08EPA 2455665
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032738016.008.1084002.06EPA 2455952
EAC4X30A+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21032751316.007.8075001.92EPA 2455986
BCE5E24M*4XAHRI reference: 21117446416.008.1085002.14EPA 2456984
EAC4X24B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21032749916.008.0082002.06EPA 2456994
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032740416.007.8079001.98EPA 2457005
EAC4X30A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21032751416.007.8075001.92EPA 2457222
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21032740116.007.8075001.92EPA 2457395
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032738116.008.1085002.06EPA 2457415
EAC4X30B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21032752916.007.8078001.96EPA 2457418
EA(C;U)1P24B+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21032739516.008.0082002.04EPA 2457421
EAC4X24B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21032749616.008.0082002.04EPA 2457656
EAC4X24A+TDR+ furnace: 80G2UH045AE12AHRI reference: 21032749316.008.1084002.06EPA 2457657
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032738816.008.0082002.08EPA 2457680
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032738316.008.0082002.04EPA 2457688
EAC4X24B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032750116.008.0082002.08EPA 2457893
BCE5V18M*4XAHRI reference: 21032737016.008.1082002.08EPA 2458120
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21032740016.007.8075001.92EPA 2458413
EAC4X24B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032749716.008.0082002.06EPA 2458473