ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 4

145 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 145 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8145 / 145
EER2 · BTU/Wh12.2–14145 / 145
HSPF2 · BTU/Wh7.8–8.5145 / 145
Cooling capacity · BTU/h18,000145 / 145
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,000145 / 145
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100145 / 145
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700145 / 145
COP at 5°F / −15°C1.9–2.16145 / 145
Equipment / loop typeHP - Split System145 / 145
Refrigerant / source-reported GWPR-410A (GWP:2088)145 / 145
Compressor stagingSingle stage145 / 145
Connected capabilityNo145 / 145

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P24A*+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21173436216.408.0080002.04EPA 2465307
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 21173433116.408.1082002.06EPA 2466174
EAH1P24B*+TDR+TXV+ furnace: 80G2UH090BE12AHRI reference: 21173443616.408.1082002.08EPA 2466604
EAH1P30B*+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21173476216.407.8078001.98EPA 2466625
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AE12AHRI reference: 21173431816.408.1082002.06EPA 2467476
EAH1P30B*+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21173486016.408.0080002.00EPA 2467483
EAH1P24B*+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21173457116.408.1082002.10EPA 2467931
EAH1P30B*+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21173481216.407.8077001.98EPA 2467945
EAD4X-30/36B+TDR+ furnace: 96G1DF045BE12AHRI reference: 21326534716.408.3087002.10EPA 2839876
7EC24BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21483159416.408.1084002.08EPA 3544438
7EC30BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21483159616.408.0078002.00EPA 3544439
7EH24BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21483160616.408.1084002.06EPA 3544442
7EH24BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21483160916.408.1084002.10EPA 3544443
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032737416.408.0082002.10EPA 3985660
EAC4X24B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21032750016.208.1082002.10EPA 2455662
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21032738716.208.1082002.10EPA 2458111
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21032737516.208.0082002.08EPA 2458414
EAC4X24A+TDR+ furnace: 80G1UH045AE12AHRI reference: 21032748816.208.0082002.08EPA 2459068
BCE7E24M*4XAHRI reference: 21185561816.208.1082002.16EPA 2464542
EAD4X-30/36B+TDR+ furnace: 96G1DF070BE16AHRI reference: 21326534816.208.4090002.08EPA 2839897

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →