Heating performance & equipment details
Ranges include the 194 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 194 / 194 |
| EER2 · BTU/Wh | 11.7–13 | 194 / 194 |
| HSPF2 · BTU/Wh | 8.1–10 | 194 / 194 |
| Cooling capacity · BTU/h | 31,000–32,800 | 194 / 194 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 194 / 194 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 194 / 194 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–29,600 | 194 / 194 |
| COP at 5°F / −15°C | 1.9–2.2 | 194 / 194 |
| Equipment / loop type | HP - Split System | 194 / 194 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 194 / 194 |
| Compressor staging | Continuously variable | 194 / 194 |
| Connected capability | Yes | 194 / 194 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3621MTANM+ furnace: R801V1005A21UHNCold climate designationAHRI reference: 216891337 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994695 → |
RCFY3621MTANM+ furnace: R98MV0703A17UPCold climate designationAHRI reference: 216891348 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994706 → |
RCFY3621MTANM+ furnace: R802V0754A17DZCold climate designationAHRI reference: 216891355 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994713 → |
RCFY3621MTANM+ furnace: R801V0755A21UHCold climate designationAHRI reference: 216891357 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994714 → |
RCFY3621MTANM+ furnace: R801V1004A17UHCold climate designationAHRI reference: 216891359 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994717 → |
RCFY3621MTANM+ furnace: R97MV0855A21DHCold climate designationAHRI reference: 216891373 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994731 → |
RCFY3621MTANM+ furnace: R98MV0855A21UPCold climate designationAHRI reference: 216891377 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994736 → |
RCFY3621MTANM+ furnace: R802V0755A21UHCold climate designationAHRI reference: 216891378 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994779 → |
RCFY3621MTANM+ furnace: R801V0754A17UHCold climate designationAHRI reference: 216891381 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994781 → |
RCFY3621MTANM+ furnace: R802V0754A17UHCold climate designationAHRI reference: 216891388 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994784 → |
RCFY3621MTANM+ furnace: R802V1004A17UHCold climate designationAHRI reference: 216891383 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994785 → |
RCFY3621MTANM+ furnace: R97MV0603A17DHCold climate designationAHRI reference: 216891393 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994790 → |
RCFY3621MTANM+ furnace: R801V1005A21DZCold climate designationAHRI reference: 216891394 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3994796 → |
RCFY3617STANM+ furnace: R801V0754A17UHCold climate designationAHRI reference: 216891479 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3994898 → |
RCFY3617STANM+ furnace: R801V0754A17DZCold climate designationAHRI reference: 216891481 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994902 → |
RCFY3621STANM+ furnace: R801V1005A21DZCold climate designationAHRI reference: 216891480 | 19.00 | 8.50 | 27400 | 2.00 | EPA 3994904 → |
RCFY3621STANM+ furnace: R921V0855A21M4Cold climate designationAHRI reference: 216891496 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994922 → |
RCFY3621STANM+ furnace: R98MV1005A21UPCold climate designationAHRI reference: 216891508 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3994936 → |
RCFY3621STANM+ furnace: R801V0754A17UHCold climate designationAHRI reference: 216891512 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3994939 → |
RCFY3621STANM+ furnace: R98MV0703A17UPCold climate designationAHRI reference: 216891531 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3995001 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.