RD18AY36AJVC
PRESTIGE SERIES · source records, page 4
194 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 194 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 194 / 194 |
| EER2 · BTU/Wh | 11.7–13 | 194 / 194 |
| HSPF2 · BTU/Wh | 8.1–10 | 194 / 194 |
| Cooling capacity · BTU/h | 31,000–32,800 | 194 / 194 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 194 / 194 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 194 / 194 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–29,600 | 194 / 194 |
| COP at 5°F / −15°C | 1.9–2.2 | 194 / 194 |
| Equipment / loop type | HP - Split System | 194 / 194 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 194 / 194 |
| Compressor staging | Continuously variable | 194 / 194 |
| Connected capability | Yes | 194 / 194 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3617STANM+ furnace: R802V1004A17UHCold climate designationAHRI reference: 216891540 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995009 → |
RCFY3621STANM+ furnace: R802V0755A21DZCold climate designationAHRI reference: 216891547 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3995018 → |
RCFY3621STANM+ furnace: R951V0855A21M4Cold climate designationAHRI reference: 216891552 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3995021 → |
RCFY3621STANM+ furnace: R802V1005A21DZCold climate designationAHRI reference: 216891554 | 19.00 | 8.50 | 27400 | 2.00 | EPA 3995023 → |
RCFY3617STANM+ furnace: R801V1004A17UHCold climate designationAHRI reference: 216891557 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995024 → |
RCFY3621STANM+ furnace: R962V0855A21M4Cold climate designationAHRI reference: 216891570 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3995031 → |
RCFY3621STANM+ furnace: R801V0754A17DZCold climate designationAHRI reference: 216891573 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995033 → |
RCFY3621STANM+ furnace: R801V1004A17UHCold climate designationAHRI reference: 216891580 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995038 → |
RCFY3617STANM+ furnace: R802V0754A17DZCold climate designationAHRI reference: 216891584 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995078 → |
RCFY3617STANM+ furnace: R802V0754A17UHCold climate designationAHRI reference: 216891582 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3995084 → |
RCFY3621STANM+ furnace: R802V0755A21UHCold climate designationAHRI reference: 216891661 | 19.00 | 8.50 | 27600 | 2.00 | EPA 3995098 → |
RCFY3617STANM+ furnace: R98MV0703A17UPCold climate designationAHRI reference: 216891666 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3995101 → |
RCFY3621STANM+ furnace: R98MV0855A21UPCold climate designationAHRI reference: 216891671 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995106 → |
RCFY3621STANM+ furnace: R802V1004A17UHCold climate designationAHRI reference: 216891679 | 19.00 | 8.50 | 27600 | 1.90 | EPA 3995109 → |
RCFY3624MTANM+ furnace: R802V1005A21UHCold climate designationAHRI reference: 216891749 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995139 → |
RCFY3624MTANM+ furnace: R801V1005A21UHSCold climate designationAHRI reference: 216891751 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995141 → |
RCFY3624MTANM+ furnace: R962V0855A21M4Cold climate designationAHRI reference: 216891752 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3995142 → |
RCFY3624MTANM+ furnace: R802V1255A24DZCold climate designationAHRI reference: 216891756 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995148 → |
RCFY3624MTANM+ furnace: R801V0755A21UHCold climate designationAHRI reference: 216891765 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3995152 → |
RCFY3617STANM+ furnace: R801V0503A14DZCold climate designationAHRI reference: 216891592 | 19.00 | 8.50 | 27800 | 1.90 | EPA 3995160 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →