RD18AY36AJVC
PRESTIGE SERIES · source records, page 2
194 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for RD18AY36AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 194 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 194 / 194 |
| EER2 · BTU/Wh | 11.7–13 | 194 / 194 |
| HSPF2 · BTU/Wh | 8.1–10 | 194 / 194 |
| Cooling capacity · BTU/h | 31,000–32,800 | 194 / 194 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–36,000 | 194 / 194 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 28,000–31,000 | 194 / 194 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–29,600 | 194 / 194 |
| COP at 5°F / −15°C | 1.9–2.2 | 194 / 194 |
| Equipment / loop type | HP - Split System | 194 / 194 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 194 / 194 |
| Compressor staging | Continuously variable | 194 / 194 |
| Connected capability | Yes | 194 / 194 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
RCFY3624MTANM+ furnace: R951V1155A24M4Cold climate designationAHRI reference: 216891831 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3994543 → |
RCFY3624MTANM+ furnace: R801V1255A24UHCold climate designationAHRI reference: 216891834 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994546 → |
RCFY3624MTANM+ furnace: R802V0755A21DZCold climate designationAHRI reference: 216891835 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994547 → |
RCFY3621MTANM+ furnace: R951V0705A21UHUCold climate designationAHRI reference: 216891252 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994571 → |
RCFY3621MTANM+ furnace: R801V0755A21DZCold climate designationAHRI reference: 216891261 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994580 → |
RCFY3621MTANM+ furnace: R97MV1005A21DHCold climate designationAHRI reference: 216891269 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994587 → |
RCFY3621MTANM+ furnace: R802V0755A21DZCold climate designationAHRI reference: 216891271 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994589 → |
RCFY3621MTANM+ furnace: R802V1005A21DZCold climate designationAHRI reference: 216891290 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3994607 → |
RCFY3621MTANM+ furnace: R962V0855A21M4Cold climate designationAHRI reference: 216891291 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994608 → |
RCFY3621MTANM+ furnace: R98MV0603A17UPCold climate designationAHRI reference: 216891295 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994611 → |
RCFY3621MTANM+ furnace: R801V1005A21UHSCold climate designationAHRI reference: 216891299 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994615 → |
RCFY3621MTANM+ furnace: R801V1005A21UHUCold climate designationAHRI reference: 216891303 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994618 → |
RCFY3621MTANM+ furnace: R951V0855A21M4Cold climate designationAHRI reference: 216891315 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994630 → |
RCFY3621MTANM+ furnace: R921V0855A21M4Cold climate designationAHRI reference: 216891319 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994633 → |
RCFY3621MTANM+ furnace: R802V1005A21UHCold climate designationAHRI reference: 216891326 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994641 → |
RCFY3624MTANM+ furnace: R97MV1155A24DHCold climate designationAHRI reference: 216891842 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994650 → |
RCFY3624MTANM+ furnace: R802V1255A24UHCold climate designationAHRI reference: 216891846 | 19.00 | 10.00 | 27800 | 2.10 | EPA 3994654 → |
RCFY3624MTANM+ furnace: R962V1155A24M4Cold climate designationAHRI reference: 216891848 | 19.00 | 10.00 | 27600 | 2.10 | EPA 3994656 → |
RH2VY3617STACNCold climate designationAHRI reference: 216891862 | 19.00 | 8.50 | 27400 | 2.00 | EPA 3994670 → |
RCFY3621MTANM+ furnace: R98MV1005A21UPCold climate designationAHRI reference: 216891335 | 19.00 | 10.00 | 28000 | 2.10 | EPA 3994692 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →