PAYNE HEATING AND COOLING / AIR-SOURCE HEAT PUMP

PH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 2

148 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity46,000–50,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 148 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18148 / 148
EER2 · BTU/Wh11.7–13.5148 / 148
HSPF2 · BTU/Wh7.8–8.5148 / 148
Cooling capacity · BTU/h46,000–50,500148 / 148
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500148 / 148
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,400148 / 148
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600148 / 148
COP at 5°F / −15°C2.1–2.32148 / 148
Equipment / loop typeHP - Split System148 / 148
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)148 / 148
Compressor stagingTwo-stage148 / 148
Connected capabilityNo148 / 148

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562380717.008.10244002.14EPA 3948367
CVAMA6021XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562394017.008.10248002.12EPA 3948553
CVAVA4924XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562450217.008.10250002.10EPA 3948741
CVAVA4924XMA*+ furnace: PG80VTLB66135D**AHRI reference: 21562453617.008.10248002.12EPA 3948776
CVAVA6021XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562482817.008.10244002.14EPA 3948873
CVAVA6021XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562493317.008.10248002.12EPA 3949074
CVAVA6021XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562474817.008.10250002.10EPA 3949152
CVAVA6021XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562476717.008.10248002.12EPA 3949174
CVAVA6121XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562514017.008.50248002.14EPA 3949352
CVAVA6124XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562542417.008.50250002.26EPA 3949370
CVAVA6124XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562564117.008.10252002.12EPA 3949417
CVAVA6121XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562527517.008.50248002.12EPA 3949576
CVAVA6121XMA*+ furnace: PG96VTAB60080C**AHRI reference: 21562533617.008.10250002.10EPA 3949707
CVAVA6121XMA*+ furnace: PG96VTAB60100C**AHRI reference: 21562535417.008.10250002.12EPA 3949727
CVAVA6124XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562548517.008.50250002.26EPA 3949818
CVAVA6124XMA*+ furnace: PG96VTAB60080C**AHRI reference: 21562571617.008.50256002.10EPA 3950044
CVAVA6124XMA*+ furnace: PG96VTAB60100C**AHRI reference: 21562573417.008.10252002.12EPA 3950062
CVAVA6021XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562886917.008.10246002.10EPA 3950412
PF5TNXC48L*AHRI reference: 21562892017.008.10246002.28EPA 3950857
CVAVA6121XMA*+ furnace: PG97VTAA60080C**AHRI reference: 21572236817.008.00250002.10EPA 3982578

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →