PAYNE HEATING AND COOLING / AIR-SOURCE HEAT PUMP

PH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 3

148 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity46,000–50,500BTU/h

Each efficiency range summarizes published EPA records for PH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 148 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18148 / 148
EER2 · BTU/Wh11.7–13.5148 / 148
HSPF2 · BTU/Wh7.8–8.5148 / 148
Cooling capacity · BTU/h46,000–50,500148 / 148
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500148 / 148
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,400148 / 148
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600148 / 148
COP at 5°F / −15°C2.1–2.32148 / 148
Equipment / loop typeHP - Split System148 / 148
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)148 / 148
Compressor stagingTwo-stage148 / 148
Connected capabilityNo148 / 148

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6121XMA*+ furnace: PG97VTAA60100C**AHRI reference: 21572238417.008.00250002.12EPA 3982597 →
CVAVA6124XMA*+ furnace: PG97VTAA60080C**AHRI reference: 21572248517.008.00256002.10EPA 3982691 →
CVAVA6124XMA*+ furnace: PG97VTAA60100C**AHRI reference: 21572250117.008.00252002.12EPA 3982708 →
CVAMA4821XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562293716.508.10246002.12EPA 3947343 →
CVAMA4821XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562297516.508.10246002.12EPA 3947379 →
CVAMA4821XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562303616.508.10244002.12EPA 3947441 →
CVAMA4821XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562305216.508.10244002.14EPA 3947459 →
CVAMA4821XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562315816.508.10244002.12EPA 3947502 →
CVAMA4921XMA*+ furnace: PG95MSUA60080C**AHRI reference: 21562352316.508.10250002.12EPA 3947833 →
CVAVA4821XMA*+ furnace: PG80VTLB60090C**AHRI reference: 21562419016.508.10244002.12EPA 3947904 →
CVAVA4821XMA*+ furnace: PG80VTLB66110C**AHRI reference: 21562420616.508.10242002.14EPA 3947923 →
CVAMA4921XMA*+ furnace: PG96VTAB60080C**AHRI reference: 21562360316.508.10250002.12EPA 3947984 →
CVAMA4921XMA*+ furnace: PG96VTAB60100C**AHRI reference: 21562362116.508.10250002.10EPA 3948003 →
CVAMA6021XMA*+ furnace: PG96VTAB60080C**AHRI reference: 21562400116.508.10248002.12EPA 3948009 →
CVAMA6021XMA*+ furnace: PG96VTAB60100C**AHRI reference: 21562401916.508.10246002.14EPA 3948031 →
CVAVA4821XMA*+ furnace: PG80MSUA48060B**AHRI reference: 21562407716.508.10242002.14EPA 3948071 →
CVAVA4821XMA*+ furnace: PG80MSUA60100C**AHRI reference: 21562411516.508.10246002.12EPA 3948110 →
CVAVA4821XMA*+ furnace: PG95MSUA60100C**AHRI reference: 21562432016.508.10244002.12EPA 3948415 →
CVAMA6021XMA*+ furnace: PG95MSUA60080C**AHRI reference: 21562392116.508.10250002.12EPA 3948532 →
CVAVA4821XMA*+ furnace: PG96VTAB60100C**AHRI reference: 21562439916.508.10244002.12EPA 3948639 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →